Literature DB >> 16306652

Spectral image reconstruction for transcranial ultrasound measurement.

Greg T Clement1.   

Abstract

An approach aimed at improved ultrasound resolution and signal strength through highly attenuating media is presented. The method delivers a series of multiple-cycle bursts in order to construct a discrete spectral (frequency domain) response in one dimension. Cross-correlation of this ultrasound A-mode response with its transmitted signal results in time-localized peaks that correspond to scattering locations. The approach is particularly relevant to the problem of transcranial ultrasound imaging, as it combines numerous smaller signals into a single signal whose net power may exceed that which could be achieved using a single burst. Tests are performed with human skull fragments and nylon-wire targets embedded in a tissue phantom. Skulls are oriented to produce both lateral and shear modes of transcranial propagation. A total of nine locations distributed over three ex vivo human skull samples are studied. Compared with pulsed and chirped signals, results indicate more localized peaks when using the multi-cycle approach, with more accurate positioning when combined with the transcranial shear mode.

Entities:  

Mesh:

Year:  2005        PMID: 16306652      PMCID: PMC1839070          DOI: 10.1088/0031-9155/50/23/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

1.  CLINICAL DIAGNOSTIC APPLICATION OF ULTRASOUND IN BRAIN DISORDERS (SONO-ENCEPHALOGRAPHY).

Authors:  C C GROSSMAN
Journal:  Dis Nerv Syst       Date:  1964-07

2.  Liquid or solid ultrasonically tissue-mimicking materials with very low scatter.

Authors:  E L Madsen; G R Frank; F Dong
Journal:  Ultrasound Med Biol       Date:  1998-05       Impact factor: 2.998

3.  Intracranial anatomy visualized in vivo by ultrasound.

Authors:  W J Fry
Journal:  Invest Radiol       Date:  1968 Jul-Aug       Impact factor: 6.016

4.  Three-dimensional ultrasound imaging of brain for neurosurgery.

Authors:  J Koivukangas; J Ylitalo; E Alasaarela; A Tauriainen
Journal:  Ann Clin Res       Date:  1986

5.  Computerized ultrasound tomography of the human head: experimental results.

Authors:  K A Dines; F J Fry; J T Patrick; R L Gilmor
Journal:  Ultrason Imaging       Date:  1981-10       Impact factor: 1.578

6.  Acoustical properties of the human skull.

Authors:  F J Fry; J E Barger
Journal:  J Acoust Soc Am       Date:  1978-05       Impact factor: 1.840

7.  Real time ultrasound tomography of the adult brain.

Authors:  S W Smith; O T von Ramm; J A Kisslo; F L Thurstone
Journal:  Stroke       Date:  1978 Mar-Apr       Impact factor: 7.914

8.  Intracranial haemodynamics in diffuse and focal brain injuries. Evaluation with transcranial Doppler (TCD) ultrasound.

Authors:  M Shigemori; T Moriyama; K Harada; N Kikuchi; T Tokutomi; S Kuramoto
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

9.  Correlation of neuropathologic findings, computerized tomographic and high-resolution ultrasound scans of canine avian sarcoma virus-induced brain tumors.

Authors:  R H Britt; B E Lyons; D R Enzmann; E L Saxer; S H Bigner; D D Bigner
Journal:  J Neurooncol       Date:  1987       Impact factor: 4.130

10.  Reliability of transcranial colour-coded real-time sonography in assessment of brain tumours: correlation of ultrasound, computed tomography and biopsy findings.

Authors:  G Becker; A Krone; D Koulis; A Lindner; E Hofmann; W Roggendorf; U Bogdahn
Journal:  Neuroradiology       Date:  1994-11       Impact factor: 2.804

View more
  4 in total

1.  Two-dimensional ultrasound detection with unfocused frequency-randomized signals.

Authors:  Gregory T Clement
Journal:  J Acoust Soc Am       Date:  2007-01       Impact factor: 1.840

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

4.  An intraoperative brain shift monitor using shear mode transcranial ultrasound: preliminary results.

Authors:  P Jason White; Stephen Whalen; Sai Chun Tang; Greg T Clement; Ferenc Jolesz; Alexandra J Golby
Journal:  J Ultrasound Med       Date:  2009-02       Impact factor: 2.153

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.