Fibrin glue and bioabsorbable felt patch for intraoperative intractable air leaks.

Hideaki Miyamoto1, Toshiroh Futagawa, Zumin Wang, Akio Yamazaki, Atsuo Morio, Satoshi Sonobe, Hiroshi Izumi, Yasuyuki Hosoda, Enjo Hata.   

Abstract

OBJECTIVE: We worked to devise a new way to prevent postoperative persistent air leaks in high-risk pulmonary surgery patients.
METHODS: From November 1993 to June 2002, 60 patients with difficult to control intraoperative pulmonary air leakage were treated using bioabsorbable polyglycolide felt patches soaked in fibrin glue to cover the leakage site.
RESULTS: After application, the felt patch adhered tightly to the lung surface without peeling off, enabling good leakage closure with only 2 ml of fibrin glue used. Air leakage was controlled successfully in 52 (86.7%) of the 60. Four of the 8 patients in whom this method failed to stop air leakage also developed mild pyothorax, with 2 requiring a second operation by video-assisted thoracic surgery. Leakage was eventually controlled in all patients, with no postoperative deaths relating to air leakage.
CONCLUSIONS: Fibrin-glue-soaked bioabsorbable felt patches effectively seal intraoperative intractable air leaks. Felt patch use may increase the risk of postoperative infection. It should be considered for use on patients with fistulas that cannot be controlled by direct closure or otherwise intraoperatively and who may potentially develop uncontrollable air leakage postoperatively.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12831236     DOI: 10.1007/s11748-003-0019-2

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  7 in total

1.  New bioabsorbable pledgets and non-woven fabrics made from polyglycolide (PGA) for pulmonary surgery: clinical experience.

Authors:  T Nakamura; Y Shimizu; S Watanabe; S Hitomi; M Kitano; J Tamada; S Matsunobe
Journal:  Thorac Cardiovasc Surg       Date:  1990-04       Impact factor: 1.827

2.  Effect of fibrin glue in the reduction of postthoracotomy alveolar air leak.

Authors:  K Wong; P Goldstraw
Journal:  Ann Thorac Surg       Date:  1997-10       Impact factor: 4.330

3.  Thoracoscopic operation for secondary pneumothorax under local and epidural anesthesia in high-risk patients.

Authors:  T Mukaida; A Andou; H Date; M Aoe; N Shimizu
Journal:  Ann Thorac Surg       Date:  1998-04       Impact factor: 4.330

4.  Treating bullous lung disease with Holmium YAG laser in conjunction with fibrin glue and DEXON mesh.

Authors:  S Kaseda; T Aoki; N Hangai; T Omoto; S Yamamoto; H Sugiura
Journal:  Lasers Surg Med       Date:  1998       Impact factor: 4.025

5.  The effect of fibrin glueing to seal bronchial and alveolar leakages after pulmonary resections and decortications.

Authors:  C Mouritzen; M Drömer; H O Keinecke
Journal:  Eur J Cardiothorac Surg       Date:  1993       Impact factor: 4.191

6.  A randomized, prospective trial of stapled lung reduction versus laser bullectomy for diffuse emphysema.

Authors:  R J McKenna; M Brenner; A F Gelb; M Mullin; N Singh; H Peters; J Panzera; J Calmese; M J Schein
Journal:  J Thorac Cardiovasc Surg       Date:  1996-02       Impact factor: 5.209

7.  Fibrin-glue-coated collagen fleece in lung surgery--experimental comparison with infrared coagulation and clinical experience.

Authors:  J R Izbicki; T Kreusser; M Meier; K L Prenzel; W T Knoefel; B Passlick; G Kuntz; U Schiele; O Thetter
Journal:  Thorac Cardiovasc Surg       Date:  1994-10       Impact factor: 1.827

  7 in total
  8 in total

Review 1.  Surgical sealant for preventing air leaks after pulmonary resections in patients with lung cancer.

Authors:  José Belda-Sanchís; Mireia Serra-Mitjans; Manuela Iglesias Sentis; Ramon Rami
Journal:  Cochrane Database Syst Rev       Date:  2010-01-20

2.  An evaluation of the surgical morbidity of polyglycolic acid felt in pulmonary resections.

Authors:  Toru Nakamura; Kazuya Suzuki; Takahiro Mochizuki; Yasuhisa Ohde; Hiroshi Kobayashi; Futoru Toyoda
Journal:  Surg Today       Date:  2010-07-30       Impact factor: 2.549

3.  Pleural defect repair with an overlapping method using fibrin glue-coated collagen fleece.

Authors:  Noriyuki Matsutani; Yuichi Ozeki
Journal:  Surg Today       Date:  2011-08-26       Impact factor: 2.549

4.  A unique method for repairing intraoperative pulmonary air leakage with both polyglycolic acid sheets and fibrin glue.

Authors:  Tokujiro Yano; Akira Haro; Yasunori Shikada; Tatsuro Okamoto; Riichiroh Maruyama; Yoshihiko Maehara
Journal:  World J Surg       Date:  2012-02       Impact factor: 3.352

5.  Clinical application of soft polyglycolic acid felt for hemostasis and repair of a lacerated liver: report of two cases.

Authors:  Markus Golling; Andre Schaudt; Arianeb Mehrabi; Zhoobin A Mood; Wolf O Bechstein
Journal:  Surg Today       Date:  2008-02-01       Impact factor: 2.549

6.  Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model.

Authors:  Takashi Sakai; Noriyuki Matsutani; Eiichi Kanai; Yoshikane Yamauchi; Hirofumi Uehara; Hisae Iinuma; Masafumi Kawamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-11-03

7.  Closure method for thick pancreas stump after distal pancreatectomy: soft coagulation and polyglycolic acid felt with fibrin glue.

Authors:  Hirofumi Akita; Hidenori Takahashi; Kunihito Gotoh; Shogo Kobayashi; Keijiro Sugimura; Norikatsu Miyoshi; Masaaki Motoori; Shingo Noura; Yoshiyuki Fujiwara; Masayuki Oue; Masahiko Yano; Masato Sakon; Osamu Ishikawa
Journal:  Langenbecks Arch Surg       Date:  2015-09-07       Impact factor: 3.445

8.  Reduction of Pulmonary Air Leaks with a Combination of Polyglycolic Acid Sheet and Alginate Gel in Rats.

Authors:  Mari Matoba; Toshitaka Takagi; Hiroyuki Tsujimoto; Yuki Ozamoto; Jo Ueda; Akeo Hagiwara
Journal:  Biomed Res Int       Date:  2018-01-02       Impact factor: 3.411

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.