Literature DB >> 12830353

A microfluidic biosensor based on nucleic acid sequence recognition.

Sylvia Kwakye1, Antje Baeumner.   

Abstract

The development of a generic semi-disposable microfluidic biosensor for the highly sensitive detection of pathogens via their nucleic acid sequences is presented in this paper. Disposable microchannels with defined areas for capture and detection of target pathogen RNA sequence were created in polydimethylsiloxane (PDMS) and mounted onto a reusable polymethylmethacrylate (PMMA) stand. Two different DNA probes complementary to unique sequences on the target pathogen RNA serve as the biorecognition elements. For signal generation and amplification, one probe is coupled to dye encapsulated liposomes while the second probe is coupled to superparamagnetic beads for target immobilization. The probes hybridize to target RNA and the liposome-target-bead complex is subsequently captured on a magnet. The amount of liposomes captured correlates directly to the concentration of target sequence and is quantified using a fluorescence microscope. Dengue fever virus serotype 3 sequences and probes were used as a model analyte system to test the sensor. Probe binding and target capture conditions were optimized for sensitivity resulting in a detection limit of as little as 10 amol microL(-1) (10 pmol L(-1)). Future biosensors will be designed to incorporate a mixer and substitute the fluorescence detection with an electrochemical detection technique to provide a truly portable microbiosensor system.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12830353     DOI: 10.1007/s00216-003-2063-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  8 in total

1.  Rapid real-time electrical detection of proteins using single conducting polymer nanowire-based microfluidic aptasensor.

Authors:  Jiyong Huang; Xiliang Luo; Innam Lee; Yushi Hu; Xinyan Tracy Cui; Minhee Yun
Journal:  Biosens Bioelectron       Date:  2011-08-19       Impact factor: 10.618

Review 2.  Dengue virus: a review on advances in detection and trends - from conventional methods to novel biosensors.

Authors:  Reza Eivazzadeh-Keihan; Paria Pashazadeh-Panahi; Tohid Mahmoudi; Karim Khanmohammadi Chenab; Behzad Baradaran; Mahmoud Hashemzaei; Fateme Radinekiyan; Ahad Mokhtarzadeh; Ali Maleki
Journal:  Mikrochim Acta       Date:  2019-05-04       Impact factor: 5.833

3.  Shadow masking for nanomaterial-based biosensors incorporated with a microfluidic device.

Authors:  Jiyong Huang; Innam Lee; Xiliang Luo; Xinyan Tracy Cui; Minhee Yun
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

Review 4.  Biosensors in clinical chemistry - 2011 update.

Authors:  Paul D'Orazio
Journal:  Clin Chim Acta       Date:  2011-06-26       Impact factor: 3.786

Review 5.  Biosensors and rapid diagnostic tests on the frontier between analytical and clinical chemistry for biomolecular diagnosis of dengue disease: a review.

Authors:  Fernando Sérgio Rodrigues Ribeiro Teles
Journal:  Anal Chim Acta       Date:  2010-12-15       Impact factor: 6.558

Review 6.  Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques.

Authors:  Om Parkash; Rafidah Hanim Shueb
Journal:  Viruses       Date:  2015-10-19       Impact factor: 5.048

7.  Enzyme-modified indium tin oxide microelectrode array-based electrochemical uric acid biosensor.

Authors:  Nidhi Puri; Vikash Sharma; Vinod K Tanwar; Nahar Singh; Ashok M Biradar
Journal:  Prog Biomater       Date:  2013-02-22

Review 8.  Emerging molecular assays for detection and characterization of respiratory viruses.

Authors:  Wenjuan Wu; Yi-Wei Tang
Journal:  Clin Lab Med       Date:  2009-12       Impact factor: 1.935

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.