Literature DB >> 12828434

Relative stiffness of beta titanium archwires.

Earl Johnson1.   

Abstract

The number of vendors of beta titanium (TMA type) wires has recently expanded dramatically. Samples of all the available sizes were obtained from most of the major beta titanium vendors. Three new square sizes are now also available. A total of 34 wire samples were tested for stiffness using the new ADA three-point wire-testing jig. Results show that not all beta titanium wires have the same stiffness. The range of variation was from small to large depending on the nominal wire size. There was also a spread of 1.67% to 4.27% in the standard deviation of the average stiffness from vendor to vendor. Burstone's Vari-modulus of elasticity is discussed along with how the properties of beta titanium could be integrated with his concepts. Strategies for using the new sizes of rectangular beta titanium wires for torque are discussed, including their use as working wires and finishing wires. The possibility of replacing stainless steel wires in the final finishing stages is also discussed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12828434     DOI: 10.1043/0003-3219(2003)073<0259:RSOBTA>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  7 in total

1.  Differences in the force system delivered by different beta-titanium wires in elaborate designs.

Authors:  Renato Parsekian Martins; Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Luís Geraldo Vaz; Roberto Hideo Shimizu; Lídia Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2015 Nov-Dec

2.  Joining characteristics of titanium-based orthodontic wires connected by laser and electrical welding methods.

Authors:  Junko Matsunaga; Ikuya Watanabe; Noriko Nakao; Etsuko Watanabe; Waleed Elshahawy; Noriaki Yoshida
Journal:  J Mater Sci Mater Med       Date:  2015-01-17       Impact factor: 3.896

3.  Mechanical properties of beta-titanium wires.

Authors:  Júlio A Gurgel; Célia R M Pinzan-Vercelino; John M Powers
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

4.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

5.  Stiffness comparison of mushroom and straight SS and TMA lingual archwires.

Authors:  Luca Lombardo; Antonella Carlucci; Mario Palone; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2016-09-12       Impact factor: 2.750

6.  Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: An in vitro study.

Authors:  Shiva Alavi; Neda Sinaee
Journal:  Dent Res J (Isfahan)       Date:  2012-09

7.  Segmented arch or continuous arch technique? A rational approach.

Authors:  Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Hallissa Simplício; André Wilson Machado
Journal:  Dental Press J Orthod       Date:  2014 Mar-Apr
  7 in total