Literature DB >> 12818956

ARX-derived auditory evoked potential index and bispectral index during the induction of anesthesia with propofol and remifentanil.

Gunter N Schmidt1, Petra Bischoff, Thomas Standl, Malte Issleib, Moritz Voigt, Jochen Schulte Am Esch.   

Abstract

UNLABELLED: A new commercial auditory evoked potential (AEP) monitor (A-line AEP monitor) was developed to calculate an index (ARX AEP index; AAI) by automatically using the amplitudes and latencies of the AEP. We investigated 30 patients before spine surgery. AAI; bispectral index (BIS); relative (%) delta, theta, alpha, and beta; spectral edge frequency; median frequency; mean arterial blood pressure; heart rate; and oxygen saturation were obtained simultaneously during stepwise (1.0 micro g/mL) induction of target-controlled propofol concentration until 5.0 micro g/mL, followed by an infusion of 0.3 micro g. kg(-1). min(-1) of remifentanil. Every minute, the patients were asked to squeeze the observer's hand. Prediction probability (Pk), receiver operating characteristic, and logistic regression were used to calculate the probability to predict the conditions AWAKE, UNCONSCIOUSNESS (first loss of hand squeeze), and steady-state ANESTHESIA (5.0 micro g/mL of propofol and 0.3 micro g. kg(-1). min(-1) of remifentanil). Although a statistically significant difference among the conditions was observed for AAI, BIS, mean arterial blood pressure, median frequency, and %alpha, only AAI and BIS were able to distinguish UNCONSCIOUSNESS versus AWAKE and ANESTHESIA versus AWAKE with better than Pk = 0.90. The modern electroencephalographic variables AAI and BIS were superior to the classic electroencephalographic and hemodynamic variables to distinguish the observed anesthetic conditions. IMPLICATIONS: The modern electroencephalographic ARX-derived auditory evoked potential index and the bispectral index were superior to the classic electroencephalographic and hemodynamic variables for predicting anesthetic conditions. Variables derived from the auditory evoked potential did not provide an advantage over variables derived from spontaneous electroencephalogram.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12818956     DOI: 10.1213/01.ane.0000065546.78919.82

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

Review 1.  [Measurement of the depth of anaesthesia].

Authors:  G N Schmidt; J Müller; P Bischoff
Journal:  Anaesthesist       Date:  2008-01       Impact factor: 1.041

2.  Comparison of the Effect of Anesthesia With Midazolam-Fentanyl Versus Propofol-Remifentanil on Bispectral Index in Patients Undergoing Coronary Artery Bypass Graft.

Authors:  Naser Hemmati; Abdol Hamid Zokaei
Journal:  Glob J Health Sci       Date:  2015-03-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.