Literature DB >> 12815686

Reduction of RF power for magnetization transfer with optimized application of RF pulses in k-space.

Chen Lin1, Matt A Bernstein, Gordon F Gibbs, John Huston.   

Abstract

More efficient use of RF power for RF-intensive applications such as magnetization transfer (MT) is necessary at high field strength (3.0 T or greater) to keep the specific absorption rate (SAR) within regulatory limits. It has been demonstrated that RF power deposition can be reduced with minimal impact on image quality by preferential application of MT pulses to the central phase-encoding views. This work extends that approach to both phase-encoding directions in a 3D acquisition (i.e., phase and slice) and further improves it by modulating the flip angle of the MT pulse according to the phase-encoded view's distance to the center of k-space. This technique is implemented for 3D time-of-flight (TOF) MR angiography (MRA) and the parameters for MT pulse are optimized based on phantom studies at 3.0 T. MT applied with this method at 3.0 T is shown to improve the blood vessel detectability in high-resolution intracranial 3D TOF MRA exams of 11 patients. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12815686     DOI: 10.1002/mrm.10513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

2.  Optimization of on-resonant magnetization transfer contrast in coronary vein MRI.

Authors:  Christian T Stoeck; Peng Hu; Dana C Peters; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Sebastian Kozerke; Reza Nezafat
Journal:  Magn Reson Med       Date:  2010-12       Impact factor: 4.668

Review 3.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

4.  To TOF or not to TOF: strategies for non-contrast-enhanced intracranial MRA at 7 T.

Authors:  Stefan Maderwald; Susanne C Ladd; Elke R Gizewski; Oliver Kraff; Jens M Theysohn; Karsten Wicklow; Christoph Moenninghoff; Isabel Wanke; Mark E Ladd; Harald H Quick
Journal:  MAGMA       Date:  2008-01-04       Impact factor: 2.310

5.  Prospective motion correction enables highest resolution time-of-flight angiography at 7T.

Authors:  Hendrik Mattern; Alessandro Sciarra; Frank Godenschweger; Daniel Stucht; Falk Lüsebrink; Georg Rose; Oliver Speck
Journal:  Magn Reson Med       Date:  2017-12-11       Impact factor: 4.668

6.  Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: impact of VERSE and sparse pulses.

Authors:  Sebastian Schmitter; Michael Bock; Sören Johst; Edward J Auerbach; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.