Assessment of myocardial lesion size during in vitro radio frequency catheter ablation.

Ding Sheng He1, Michael Bosnos, Mary Z Mays, Frank Marcus.   

Abstract

We report our experience with a system that utilizes changes in several biophysical characteristics of cardiac tissue to determine lesion formation and to estimate lesion size both on and off-line in vitro during radio frequency (RF) energy delivery. We analyzed the reactive and resistive components of tissue impedance and tracked the change of phase angle during RF ablation. We correlated the amount of tissue damage with these and other biophysical parameters and compared them with off-line analysis. We found that there are irreversible changes in the reactive and resistive components of impedance that occurred during tissue ablation. The irreversible changes of these components are greater in magnitude, and correlate better with the size of lesions than that of impedance alone that is currently used. Numerically, the best single on-line and off-line correlation for combined perpendicular and parallel electrode orientation was with phase angle. On-line and off-line capacitance and susceptance correlations were essentially similar suggesting that they may be useful as lesion size predictors, given these parameter's persistent change without temperature sensitivity. This study indicates that it is technically feasible to assess lesion formation using biophysical parameters.

Entities:  

Mesh:

Year:  2003        PMID: 12814243     DOI: 10.1109/TBME.2003.812161

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Mathematical models based on transfer functions to estimate tissue temperature during RF cardiac ablation in real time.

Authors:  Jose Alba-Martínez; Macarena Trujillo; Ramon Blasco-Gimenez; Enrique Berjano
Journal:  Open Biomed Eng J       Date:  2012-03-08

Review 2.  The challenge of optimising ablation lesions in catheter ablation of ventricular tachycardia.

Authors:  Riccardo Proietti; Luca Lichelli; Nicolas Lellouche; Tarvinder Dhanjal
Journal:  J Arrhythm       Date:  2020-12-28

3.  Introducing a novel catheter-tissue contact feedback feature in robotic navigated catheter ablation: Utility, feasibility, and safety.

Authors:  Anna Maria Elisabeth Noten; Tamas Géczy; Sing-Chien Yap; Zsuzsanna Kis; Tamas Szili-Torok
Journal:  Heart Rhythm O2       Date:  2020-05-11

4.  The impacts of contact force, power and application time on ablation effect indicated by serial measurements of impedance drop in both conventional and high-power short-duration ablation settings of atrial fibrillation.

Authors:  Li-Bin Shi; Yu-Chuan Wang; Song-Yun Chu; Alessandro De Bortoli; Peter Schuster; Eivind Solheim; Jian Chen
Journal:  J Interv Card Electrophysiol       Date:  2021-04-23       Impact factor: 1.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.