Literature DB >> 12812446

Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations.

Ryosuke Kohno1, Yoshihisa Takada, Takeji Sakae, Toshiyuki Terunuma, Keiji Matsumoto, Akihiro Nohtomi, Hiroyuki Matsuda.   

Abstract

It is important for proton therapy to calculate dose distributions accurately in treatment planning. Dose calculations in the body for treatment planning are converted to dose distributions in water, and the converted calculations are then generally evaluated by the dose measurements in water. In this paper, proton dose calculations were realized for a phantom simulating a clinical heterogeneity. Both dose calculations in the phantom calculated by two dose calculation methods, the range-modulated pencil beam algorithm (RMPBA) and the simplified Monte Carlo (SMC) method, and dose calculations converted to dose distributions in water by the same two methods were verified experimentally through comparison with measured distributions, respectively. For the RMPBA, though the converted calculations in water agreed moderately well with the measured ones, the calculated results in the actual phantom produced large errors. This meant that dose calculations in treatment planning should be evaluated by the dose measurements not in water but in the body with heterogeneity. On the other hand, the results calculated in the phantom, even by the less rigorous SMC method, reproduced the experimental ones well. This finding showed that actual dose distributions in the body should be predicted by the SMC method.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12812446     DOI: 10.1088/0031-9155/48/10/303

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations.

Authors:  Pablo P Yepes; Dragan Mirkovic; Phillip J Taddei
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

Review 2.  GPU-based high-performance computing for radiation therapy.

Authors:  Xun Jia; Peter Ziegenhein; Steve B Jiang
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

3.  Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

4.  Recent developments and comprehensive evaluations of a GPU-based Monte Carlo package for proton therapy.

Authors:  Nan Qin; Pablo Botas; Drosoula Giantsoudi; Jan Schuemann; Zhen Tian; Steve B Jiang; Harald Paganetti; Xun Jia
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

5.  GPU-based fast Monte Carlo dose calculation for proton therapy.

Authors:  Xun Jia; Jan Schümann; Harald Paganetti; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-11-06       Impact factor: 3.609

6.  In vivo proton dosimetry using a MOSFET detector in an anthropomorphic phantom with tissue inhomogeneity.

Authors:  Ryosuke Kohno; Kenji Hotta; Kana Matsubara; Shie Nishioka; Taeko Matsuura; Mitsuhiko Kawashima
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

7.  A simplified Monte Carlo algorithm considering large-angle scattering for fast and accurate calculation of proton dose.

Authors:  Taisuke Takayanagi; Shusuke Hirayama; Shinichiro Fujitaka; Rintaro Fujimoto
Journal:  J Appl Clin Med Phys       Date:  2017-11-27       Impact factor: 2.102

8.  Evaluation of monitor unit calculation based on measurement and calculation with a simplified Monte Carlo method for passive beam delivery system in proton beam therapy.

Authors:  Kenji Hotta; Ryosuke Kohno; Kohsuke Nagafuchi; Hidenori Yamaguchi; Ryohei Tansho; Yoshihisa Takada; Tetsuo Akimoto
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

9.  Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

Authors:  Ryosuke Kohno; Kenji Hotta; Taeko Matsuura; Kana Matsubara; Shie Nishioka; Teiji Nishio; Mitsuhiko Kawashima; Takashi Ogino
Journal:  J Appl Clin Med Phys       Date:  2011-04-04       Impact factor: 2.102

10.  Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams.

Authors:  Shohei Mizutani; Yoshihisa Takada; Ryosuke Kohno; Kenji Hotta; Ryohei Tansho; Tetsuo Akimoto
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.