Literature DB >> 12807139

Diffusion NMR methods applied to xenon gas for materials study.

R W Mair1, M S Rosen, R Wang, D G Cory, R L Walsworth.   

Abstract

We report initial NMR studies of (i) xenon gas diffusion in model heterogeneous porous media and (ii) continuous flow laser-polarized xenon gas. Both areas utilize the pulsed gradient spin-echo (PGSE) techniques in the gas phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients--a brief overview of this area is provided in the Introduction. The heterogeneous or multiple-length scale model porous media consisted of random packs of mixed glass beads of two different sizes. We focus on observing the approach of the time-dependent gas diffusion coefficient, D(t) (an indicator of mean squared displacement), to the long-time asymptote, with the aim of understanding the long-length scale structural information that may be derived from a heterogeneous porous system. We find that D(t) of imbibed xenon gas at short diffusion times is similar for the mixed bead pack and a pack of the smaller sized beads alone, hence reflecting the pore surface area to volume ratio of the smaller bead sample. The approach of D(t) to the long-time limit follows that of a pack of the larger sized beads alone, although the limiting D(t) for the mixed bead pack is lower, reflecting the lower porosity of the sample compared to that of a pack of mono-sized glass beads. The Pade approximation is used to interpolate D(t) data between the short- and long-time limits. Initial studies of continuous flow laser-polarized xenon gas demonstrate velocity-sensitive imaging of much higher flows than can generally be obtained with liquids (20-200 mm s-1). Gas velocity imaging is, however, found to be limited to a resolution of about 1 mm s-1 owing to the high diffusivity of gases compared with liquids. We also present the first gas-phase NMR scattering, or diffusive-diffraction, data, namely flow-enhanced structural features in the echo attenuation data from laser-polarized xenon flowing through a 2 mm glass bead pack. c2002 John Wiley & Sons, Ltd.

Entities:  

Keywords:  NASA Discipline Life Sciences Technologies; Non-NASA Center

Mesh:

Substances:

Year:  2002        PMID: 12807139     DOI: 10.1002/mrc.1114

Source DB:  PubMed          Journal:  Magn Reson Chem        ISSN: 0749-1581            Impact factor:   2.447


  4 in total

1.  Improved diffusion measurement in heterogeneous systems using the magic asymmetric gradient stimulated echo (MAGSTE) technique.

Authors:  Phillip Zhe Sun
Journal:  J Magn Reson       Date:  2007-04-27       Impact factor: 2.229

Review 2.  Intravoxel Incoherent Motion Magnetic Resonance Imaging in Skeletal Muscle: Review and Future Directions.

Authors:  Erin K Englund; David A Reiter; Bahar Shahidi; Eric E Sigmund
Journal:  J Magn Reson Imaging       Date:  2021-08-14       Impact factor: 5.119

3.  MR imaging of apparent 3He gas transport in narrow pipes and rodent airways.

Authors:  Kevin R Minard; Richard E Jacob; Gernot Laicher; Daniel R Einstein; Andrew P Kuprat; Richard A Corley
Journal:  J Magn Reson       Date:  2008-07-13       Impact factor: 2.229

4.  Impact of Defects and Crystal Size on Negative Gas Adsorption in DUT-49 Analyzed by In Situ 129Xe NMR Spectroscopy.

Authors:  Simon Krause; Florian S Reuter; Sebastian Ehrling; Volodymyr Bon; Irena Senkovska; Stefan Kaskel; Eike Brunner
Journal:  Chem Mater       Date:  2020-05-11       Impact factor: 9.811

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.