Literature DB >> 12804331

The psychosocial impact of the implantable cardioverter defibrillator: a meta-analytic review.

J L Burke1, C N Hallas, D Clark-Carter, D White, D Connelly.   

Abstract

OBJECTIVE: The implantable cardioverter defibrillator (ICD) has become the treatment of choice for ventricular arrhythmia (VA; abnormal heart rhythms) and the prevention of sudden cardiac death (SCD). Recent clinical trials have shown the ICD to be superior to anti-arrhythmic medication in reducing mortality; however, research has suggested that ICD recipients experience poor psychosocial adjustment following implantation of the device. This aim of this study was to identify the key psychological characteristics associated with ICD implantation and to establish whether poor psychosocial outcome can be attributed directly to the device and its therapy.
METHOD: Studies which reported valid and reliable measures of psychological functioning in ICD patients and appropriate comparison groups were considered for inclusion in a meta-analytic review. A systematic search of electronic databases and reference lists identified 20 studies which fulfilled the inclusion criteria.
RESULTS: There were no significant differences in psychosocial outcome between ICD patients and drug-maintained VA patients or between pre- and post-implant ICD patients. However, ICD patients reported significantly worse psychological functioning and physical functioning than other cardiac controls.
CONCLUSION: These findings suggest that poor psychosocial outcome in ICD patients may occur as a result of variables associated with the underlying VA condition, rather than as a direct response to implantation of the device and its therapy. This holds important implications for the development and implementation of psychological interventions for patients experiencing VA, in preference to ICD-specific programmes.

Entities:  

Mesh:

Year:  2003        PMID: 12804331     DOI: 10.1348/135910703321649141

Source DB:  PubMed          Journal:  Br J Health Psychol        ISSN: 1359-107X


  16 in total

1.  Patients' perspectives on end-of-life issues and implantable cardioverter defibrillators.

Authors:  Patricia H Strachan; Sandra L Carroll; Sonya de Laat; Lisa Schwartz; Heather M Arthur
Journal:  J Palliat Care       Date:  2011       Impact factor: 2.250

2.  Implantable cardioverter-defibrillators for children and young adolescents: mortality benefit confirmed--what's next?

Authors:  S F Sears; J B Conti
Journal:  Heart       Date:  2004-03       Impact factor: 5.994

3.  Sudden cardiac death: opportunities for prevention.

Authors:  J M Morgan; J C Cowan; A J Camm; J M McComb
Journal:  Heart       Date:  2005-09-13       Impact factor: 5.994

4.  Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

Authors:  S Arnous; N F Murphy; P Pyne-Daly; Z Nawoor; D Keane; M Ledwidge; K McDonald
Journal:  Ir J Med Sci       Date:  2010-12-14       Impact factor: 1.568

5.  Cost-effectiveness of implantable cardioverter-defibrillators in children with dilated cardiomyopathy.

Authors:  Brian Feingold; Gaurav Arora; Steven A Webber; Kenneth J Smith
Journal:  J Card Fail       Date:  2010-06-08       Impact factor: 5.712

6.  Quality of life and psychological status of patients with implantable cardioverter defibrillators.

Authors:  E Friedmann; S A Thomas; P Inguito; C W Kao; M Metcalf; F J Kelley; S S Gottlieb
Journal:  J Interv Card Electrophysiol       Date:  2007-01-18       Impact factor: 1.900

7.  Psychosocial and cardiac outcomes of yoga for ICD patients: a randomized clinical control trial.

Authors:  Stefanie C F Toise; Samuel F Sears; Mark H Schoenfeld; Mark L Blitzer; Mark A Marieb; John H Drury; Martin D Slade; Thomas J Donohue
Journal:  Pacing Clin Electrophysiol       Date:  2013-08-26       Impact factor: 1.976

8.  Psychological functioning and disease-related quality of life in pediatric patients with an implantable cardioverter defibrillator.

Authors:  H M Koopman; C M J Vrijmoet-Wiersma; J N D Langius; F van den Heuvel; S A Clur; C A Blank; N A Blom; A D J ten Harkel
Journal:  Pediatr Cardiol       Date:  2012-04       Impact factor: 1.655

Review 9.  Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD) A systematic review.

Authors:  Elena Salmoirago-Blotcher; Ira S Ockene
Journal:  BMC Cardiovasc Disord       Date:  2009-12-29       Impact factor: 2.298

10.  Comparative Study between Subcutaneous and Endovascular Defibrillator Recipients Regarding Tolerance to the Implant Procedure and Perception of Quality of Life.

Authors:  Pablo Esteban Auquilla-Clavijo; Naiara Calvo-Galiano; Marina Povar-Echeverría; Teresa Oloriz-Sanjuan; Francisco Diaz-Cortejana; Antonio Asso-Abadia
Journal:  Arq Bras Cardiol       Date:  2021-06       Impact factor: 2.000

View more