Interaction between permanent cardiac pacing and electrocautery: the significance of electrode position.

M Chauvin1, F Crenner, C Brechenmacher.   

Abstract

The danger in utilizing electrocautery during a surgical procedure on a pacemaker patient depends, to a great extent, on the position of the electrodes. We have studied this influence in an experimental model consisting of a plexiglass tank filled with a saline solution. Seven pacemakers were successively attached to an immersed and fixed frame and connected to a lead whose tip remains in the same location throughout the experiments. An ERBOTOM T 400 C generator (450 kHz) was used in an unmodulated unipolar mode at a maximum output (400 W). The high frequency current was delivered between a patch located successively at six preset positions in the tank and another electrode applied to 176 surface locations. For each position, we measured the currents in the lead with a separate measurement circuit connected in parallel on the same lead. Results were displayed on a map. Regardless of the patch position, currents were: (1) at a maximum when high frequency was delivered close to the pacemakers and around the tip of the lead; (2) negligible when applied to the path followed by the lead; and (3) a function of the distance between electrodes. These results may help to formulate recommendations to prevent accidents when using electrocautery in pacemaker patients.

Entities:  

Mesh:

Year:  1992        PMID: 1279593     DOI: 10.1111/j.1540-8159.1992.tb03015.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Reversible prolonged pacemaker failure due to electrocautery.

Authors:  R W Peters; M R Gold
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

Review 2.  [Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators. Recommendations of the Austrian Society for Anaesthesiology, Resuscitation and Intensive Care Medicine, the Austrian Society for Cardiology and the Austrian Society for Surgery].

Authors:  H Gombotz; M Anelli Monti; N Leitgeb; M Nürnberg; B Strohmer
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

3.  [Does thermotherapy of prostatic hypertrophy interfere with pacemaker function? - First results of a pilot-study].

Authors:  G Jakl; M Nürnberg; K Steinbach; G Theyer; O Zechner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

Review 4.  Management of cardiac implantable electronic devices during interventional pulmonology procedures.

Authors:  Abhishek Kumar; Samjot Singh Dhillon; Spandan Patel; Matthias Grube; Amit Noheria
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895