Precision of impedance cardiography measurements of cardiac output in pacemaker patients.

I Ovsyshcher1, J N Gross, S Blumberg, S Furman.   

Abstract

Objective hemodynamic assessment of pacemaker patients is necessary for gauging responses to changes in programming or other conditions that affect the circulation. Impedance cardiography permits noninvasive, repetitive determinations of cardiac output at short intervals, but data regarding variability of this method in patients with pacemakers is unavailable. Thirty-eight patients with implanted pacemakers (24 DDD, 14 VVI) and six normal subjects were studied. A computerized impedance cardiograph was used to calculate cardiac output from the product of the first derivative of the thoracic impedance signal (dZ/dt), the ventricular ejection time, and heart rate. Each patient was studied while supine after a period of at least 15 minutes of rest and repeated impedance measurements (about ten) were performed. Fourteen patients were studied in sinus rhythm, 24 were studied during DDD pacing, and 32 patients were studied during VVI pacing. Cardiac and stroke indices were calculated 706 times on the basis of 11,296 accepted beats. Variability was assessed by methods that analyzed serial measurements and variability between two consecutive and nonconsecutive measurements. The mean indices and coefficients of variation of two measurements and of serial measurements in sinus rhythm and during DDD pacing were 4%; in VVI it was 6%. The precision of impedance cardiography in all pacing modes, as demonstrated by analysis of variability, indicates that detected changes of stroke volume and cardiac output > 7% on serial (two and more) measurements, performed by the same operator and during the same session, represent true hemodynamic alterations with 95% confidence.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1279573     DOI: 10.1111/j.1540-8159.1992.tb02995.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Comparison of the acute hemodynamic effect of right ventricular apex, outflow tract, and dual-site right ventricular pacing.

Authors:  Andrzej Rubaj; Piotr Rucinski; Tomasz Sodolski; Andrzej Bilan; Marcin Gulaj; Alicja Dabrowska-Kugacka; Andrzej Kutarski
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

2.  Effects of AV-delay optimization on hemodynamic parameters in patients with VDD pacemakers.

Authors:  Konstantin A Krychtiuk; Michael Nürnberg; Romana Volker; Linda Pachinger; Rudolf Jarai; Matthias K Freynhofer; Johann Wojta; Kurt Huber; Thomas W Weiss
Journal:  Wien Klin Wochenschr       Date:  2014-03-21       Impact factor: 1.704

3.  Impact of a right ventricular impedance sensor on the cardiovascular responses to exercise in pacemaker dependent patients.

Authors:  Linnea Cook; Corey Tomczak; Edward Busse; John Tsang; Wladyslaw Wojcik; Robert Haennel
Journal:  Indian Pacing Electrophysiol J       Date:  2005-07-01

Review 4.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.