Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators.

W Grimm1, B F Flores, F E Marchlinski.   

Abstract

The incidence and cause of electrocardiographically documented spontaneous implantable cardioverter defibrillator (ICD) discharges for a rhythm other than ventricular tachycardia (VT) or fibrillation (VF) (unnecessary shocks) were determined in 241 patients who underwent ICD implantation between March 1983 and November 1991. During follow-up of 24 +/- 20 months, 54 of 241 patients (22%) received a total of 132 unnecessary ICD shocks confirmed by Holter or telemetry monitoring or stored electrograms (Egs) from the ICD. The rhythm preceding these unnecessary ICD shocks was atrial fibrillation in 30 patients, sinus or supraventricular tachycardia (SVT) in 11 patients, antitachycardia pacing triggered by atrial fibrillation or SVT resulting in VT in 5 patients, nonsustained VT in 3 patients, and normal sinus or pacemaker rhythm in 10 patients. Unnecessary ICD discharges occurred most frequently during the first week after implantation or generator replacement (18 of 54 patients [33%]). Unnecessary ICD discharges could be documented more often by stored Egs in patients with devices with Eg storage capability (Ventritex Cadence, 19 of 54 patients [35%]) than by Holter or telemetry monitoring in patients with devices without Egs storage capabilities (34 of 193 patients [18%], P < 0.01), despite a shorter mean follow-up duration of 14 +/- 9 months versus 26 +/- 21 months, respectively. Only six of 54 patients (11%) in whom unnecessary ICD discharges occurred had recurrent unnecessary shocks during 22 +/- 20 months of follow-up after treatment directed at the cause of the first episode or device reprogramming to preclude non-VT rhythm detection.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1279533     DOI: 10.1111/j.1540-8159.1992.tb02953.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  24 in total

1.  Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment.

Authors:  L Lickfett; C Wolpert; W Jung; S Spehl; L Pizzulli; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1999-07       Impact factor: 1.900

2.  Atrial defibrillation at the millennium: new challenges for evolving technology.

Authors:  R Boccadamo
Journal:  J Interv Card Electrophysiol       Date:  2000-04       Impact factor: 1.900

3.  Prospective evaluation of the quality and long-term stability of atrial signals in non-thoracotomy defibrillation electrodes: comparison of four different endocardial electrograms.

Authors:  C Wolpert; W Jung; S Spehl; B Schumacher; H Omran; B Esmailzadeh; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-12       Impact factor: 1.900

Review 4.  Implantable dual-chamber cardioverter-defibrillator-pacemaker.

Authors:  D Pfeiffer; M Mende; A Hagendorff
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

5.  A 17 year experience of inappropriate shock therapy in patients with implantable cardioverter-defibrillators: are we getting any better?

Authors:  C A Rinaldi; R D Simon; A Baszko; J Bostock; D Elliot; C A Bucknall; J S S Gill
Journal:  Heart       Date:  2004-03       Impact factor: 5.994

6.  [Not Available].

Authors:  D G Meininghaus; M Volkmer; K H Kuck
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1998-02

7.  Case report: inappropriate discharge of an implantable cardioverter-defibrillator caused by the combined count criterion.

Authors:  C Wolpert; W Jung; S Spehl; T Korte; B Lüderitz
Journal:  J Interv Card Electrophysiol       Date:  1998-03       Impact factor: 1.900

8.  Clinical benefit, survival and adverse events in patients with implantable cardioverter defibrillators: the initial Rotterdam experience.

Authors:  D A M J Theuns; A P J Klootwijk; G P Kimman; M L Simoons; J R T C Roelandt; L J L M Jordaens
Journal:  Neth Heart J       Date:  2001-09       Impact factor: 2.380

9.  Multicenter automatic defibrillator implantation trial: reduce inappropriate therapy (MADIT-RIT): background, rationale, and clinical protocol.

Authors:  Claudio Schuger; James P Daubert; Mary W Brown; David Cannom; N A Mark Estes; W Jackson Hall; Torsten Kayser; Helmut Klein; Brian Olshansky; Keith A Power; David Wilber; Wojciech Zareba; Arthur J Moss
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-07       Impact factor: 1.468

10.  [New algorithms for discrimination between supraventricular and ventricular tachyarrhythmias in patients with implantable cardioverter/defibrillator].

Authors:  J Neuzner; M Schlepper
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03