Literature DB >> 12794239

Hip fracture discrimination study: QUS of the radius and the calcaneum.

Didier Hans1, Laurence Genton, Samia Allaoua, Claude Pichard, Daniel O Slosman.   

Abstract

As an emerging alternative to current radiation-based bone densitometry techniques, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the noninvasive assessment of fracture risk in the management of osteoporosis. However, there are also a multiplicity of technologically different QUS devices available on the market and, so far, no study has compared heel and radius QUS device for the discrimination of subjects with hip fractures. Our study evaluated the ability of three QUS devices (one calcaneal gel-coupled system, one calcaneal water-coupled system, and one radius system) to discriminate osteoporotic from controls subjects, using the same population. We also checked if the combination of two different skeletal sites (i.e., calcaneum and radius) improve the discriminatory ability of the QUS devices. Forty-five women aged 79.1+/-7.1 yr with hip fractures within the last 4 d were used as the hip-fracture group and compared to 40 healthy controls from 65-87 yr. In addition, 47 young controls, aged 20-40 yr, were used as reference population to express some of the results as T-scores. QUS measurements were performed with the Hologic Sahara, Ge-Lunar Achilles+, and Sunlight Omnisense devices according to the manufacturer's recommendations. Adjusted odds ratio results showed that a decrease in Omnisense SOS of 1 standard deviation (SD) was associated with a significant increase in fracture risk (OR adj.=2.83) comparable with Sahara BUA (OR adj.=2.42) and Achilles BUA (OR adj.=3.29). However, given the large overlap between the 95% intervals of each odds ratio, no significant difference was found between the devices. Similarly, comparison between the areas under ROC curves did not show any significant difference between all the parameters. Considering the parameters provided per default by each QUS device, the Sahara, Achilles, and Omnisense devices classified correctly 70, 67.5, and 62.5% of the subjects, respectively. Although the OR of the combination of radius and calcaneum is improved (3.62 to 4.74) compared with either one of the single skeletal site, the large confidence intervals do not allow to claim a significant difference. The three QUS technologies tested against hip fractures seem to show the same discriminatory ability. However, there is some differences in the definition of the diagnostic threshold underlying the nonusability of the World Health Organization (WHO) osteoporosis definition. Finally the combination of several site using two different devices is not clinically relevant. Potential interest could be seen in combining several sites using the same device, supposing that such device would measure differently active bone.

Entities:  

Mesh:

Year:  2003        PMID: 12794239     DOI: 10.1385/jcd:6:2:163

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.963


  8 in total

1.  Low-frequency axial ultrasound velocity correlates with bone mineral density and cortical thickness in the radius and tibia in pre- and postmenopausal women.

Authors:  V Kilappa; P Moilanen; L Xu; P H F Nicholson; J Timonen; S Cheng
Journal:  Osteoporos Int       Date:  2010-06-25       Impact factor: 4.507

2.  Discrimination of fractures by low-frequency axial transmission ultrasound in postmenopausal females.

Authors:  P Moilanen; M Määttä; V Kilappa; L Xu; P H F Nicholson; M Alén; J Timonen; T Jämsä; S Cheng
Journal:  Osteoporos Int       Date:  2012-05-26       Impact factor: 4.507

3.  Quantitative Ultrasound (QUS) in the Management of Osteoporosis and Assessment of Fracture Risk: An Update.

Authors:  Didier Hans; Antoine Métrailler; Elena Gonzalez Rodriguez; Olivier Lamy; Enisa Shevroja
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

4.  Long-Term Sex-Specific Effects of Cadmium Exposure on Osteoporosis and Bone Density: A 10-Year Community-Based Cohort Study.

Authors:  Seung Min Chung
Journal:  J Clin Med       Date:  2022-05-20       Impact factor: 4.964

5.  Multisite quantitative ultrasound for the prediction of fractures over 5 years of follow-up: the Canadian Multicentre Osteoporosis Study.

Authors:  Wojciech P Olszynski; Jacques P Brown; Jonathan D Adachi; David A Hanley; George Ioannidis; Kenneth S Davison
Journal:  J Bone Miner Res       Date:  2013-09       Impact factor: 6.741

6.  Epidemiological survey of quantitative ultrasound in risk assessment of falls in middle-aged and elderly people.

Authors:  Ling-Chun Ou; Zih-Jie Sun; Yin-Fan Chang; Chin-Sung Chang; Ting-Hsing Chao; Po-Hsiu Kuo; Ruey-Mo Lin; Chih-Hsing Wu
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

7.  High dairy products intake reduces osteoporosis risk in Korean postmenopausal women: A 4 year follow-up study.

Authors:  Seon-Joo Park; Ji Hye Jung; Myung-Sunny Kim; Hae-Jeung Lee
Journal:  Nutr Res Pract       Date:  2018-10-01       Impact factor: 1.926

8.  Association between low-frequency ultrasound and hip fractures -- comparison with DXA-based BMD.

Authors:  Mikko Määttä; Petro Moilanen; Jussi Timonen; Pasi Pulkkinen; Raija Korpelainen; Timo Jämsä
Journal:  BMC Musculoskelet Disord       Date:  2014-06-16       Impact factor: 2.362

  8 in total