Literature DB >> 12790466

Optode positional calibration in diffuse optical tomography.

Jonathan J Stott1, Joseph P Culver, Simon R Arridge, David A Boas.   

Abstract

Although diffuse optical tomography is a highly promising technique used to noninvasively image blood volume and oxygenation, the reconstructed data are sensitive to systemic difference between the forward model and the actual experimental conditions. In particular, small changes in optode location or in the optode-tissue coupling coefficient significantly degrade the quality of the reconstruction images. Accurate system calibration therefore is an essential part of any experimental protocol. We present a technique for simultaneously calibrating optode positions and reconstructing images that significantly improves image quality, as we demonstrate with simulations and phantom experiments.

Mesh:

Year:  2003        PMID: 12790466     DOI: 10.1364/ao.42.003154

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

Review 1.  Implicit and explicit prior information in near-infrared spectral imaging: accuracy, quantification and diagnostic value.

Authors:  Brian W Pogue; Scott C Davis; Frederic Leblond; Michael A Mastanduno; Hamid Dehghani; Keith D Paulsen
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

2.  Compensation of optode sensitivity and position errors in diffuse optical tomography using the approximation error approach.

Authors:  Meghdoot Mozumder; Tanja Tarvainen; Simon R Arridge; Jari Kaipio; Ville Kolehmainen
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

3.  Implementation of a computationally efficient least-squares algorithm for highly under-determined three-dimensional diffuse optical tomography problems.

Authors:  Phaneendra K Yalavarthy; Daniel R Lynch; Brian W Pogue; Hamid Dehghani; Keith D Paulsen
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Sensitivity Uniformity Ratio as a New Index to Optimize the Scanning Geometry for Fluorescent Molecular Tomography.

Authors:  Anita Ebrahimpour; Seyed Salman Zakariaee; Marjaneh Hejazi
Journal:  J Med Signals Sens       Date:  2019 Jan-Mar

5.  Reducing image artifact in diffuse optical tomography by iterative perturbation correction based on multiwavelength measurements.

Authors:  K M Shihab Uddin; Quing Zhu
Journal:  J Biomed Opt       Date:  2019-05       Impact factor: 3.170

6.  A Data Self-Calibration Method Based on High-Density Parallel Plate Diffuse Optical Tomography for Breast Cancer Imaging.

Authors:  Xin Wang; Rui Hu; Yirong Wang; Qiang Yan; Yihan Wang; Fei Kang; Shouping Zhu
Journal:  Front Oncol       Date:  2021-12-21       Impact factor: 6.244

7.  An Automated Preprocessing Method for Diffuse Optical Tomography to Improve Breast Cancer Diagnosis.

Authors:  Murad Althobaiti; Hamed Vavadi; Quing Zhu
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

8.  Using anatomically defined regions-of-interest to adjust for head-size and probe alignment in functional near-infrared spectroscopy.

Authors:  Xuetong Zhai; Hendrik Santosa; Theodore J Huppert
Journal:  Neurophotonics       Date:  2020-09-23       Impact factor: 3.593

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.