Literature DB >> 12788176

Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy.

Vincent M Remouchamps1, Nicola Letts, Frank A Vicini, Michael B Sharpe, Larry L Kestin, Peter Y Chen, Alvaro A Martinez, John W Wong.   

Abstract

INTRODUCTION: We present our initial clinical experience using moderate deep-inspiration breath hold (mDIBH) with an active breathing control (ABC) device to reduce heart dose in the treatment of patients with early-stage, left-sided breast cancer using external beam radiation therapy (EBRT) limited to the whole breast. METHODS AND MATERIALS: Between February and August 2002, 5 patients with Stages I/II left-sided breast cancer received EBRT limited to the whole breast using an ABC device. After standard virtual simulation, patients with >2% of the heart receiving >30 Gy in free breathing were selected. All patients underwent a training session with the ABC apparatus to determine their ability to comfortably maintain mDIBH at 75% of the maximum inspiration capacity. Three patients received 45 Gy to the whole breast in 25 fractions, and 2 patients received 50.4 Gy in 28 fractions. For each of the medial and lateral tangential beams, radiation was delivered during 2 or 3 breath hold durations that ranged from 18 to 26 s. "Step-and-shoot" intensity modulation was employed to achieve uniform dose distribution. Open beam segments were purposely delivered over 2 breath hold sessions and captured on electronic portal images to allow intra- and interfraction setup error analysis. All electronic portal images of the tangential beams were analyzed off-line using an in-house treatment verification tool to assess the anteroposterior, craniocaudal, and rotational uncertainties. Corrections were applied if necessary.
RESULTS: A comparison of treatment plans performed on breath-hold and free-breathing CTs showed that ABC treatments achieved a mean absolute reduction of 3.6% in heart volume receiving 30 Gy (heart V(30)) and 1.5% in the heart normal tissue complication probability. A total of 134 ABC treatment sessions were performed in the 5 patients. The average number of breath holds required per beam direction was 2.5 (4-6 per treatment) with a median duration of 22 s per breath hold (range: 10-26 s). Patients tolerated mDIBH well. The median treatment time was 18.2 min (range: 13-32 min), which was progressively shortened with increasing experience. A total of 509 portal images were analyzed. Combining measurements for all patients, the interfraction setup errors (1 SD) in the lateral and craniocaudal directions and in rotation were 2.4 mm, 3.2 mm, and 1 degrees, respectively, for the medial beam and 2.3 mm, 3.1 mm, and 1 degrees, respectively, for the lateral beam. For all patients, the intrafraction setup errors were about 1 mm and always less than 2 mm (1 SD).
CONCLUSION: Reduction in heart V(30) can be achieved in patients with left-sided breast cancer using mDIBH assisted with an ABC device. With increasing experience, ABC treatments were streamlined and could be performed within a 15-min treatment slot. Our results suggest that mDIBH using an ABC device may provide one of the most promising methods of improving the efficacy of EBRT in patients with left-sided breast cancer, particularly when wide tangential beams are employed. Breast cancer; Breath hold; Radiation therapy; Intensity modulated radiation therapy

Entities:  

Mesh:

Year:  2003        PMID: 12788176     DOI: 10.1016/s0360-3016(03)00010-5

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  38 in total

1.  Six-year experience routinely using moderate deep inspiration breath-hold for the reduction of cardiac dose in left-sided breast irradiation for patients with early-stage or locally advanced breast cancer.

Authors:  Todd Swanson; Inga S Grills; Hong Ye; Amy Entwistle; Melanie Teahan; Nicola Letts; Di Yan; Joana Duquette; Frank A Vicini
Journal:  Am J Clin Oncol       Date:  2013-02       Impact factor: 2.339

2.  Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: system development and feasibility.

Authors:  Tadamasa Yoshitake; Katsumasa Nakamura; Yoshiyuki Shioyama; Satoshi Nomoto; Saiji Ohga; Takashi Toba; Takehiro Shiinoki; Shigeo Anai; Hiromi Terashima; Junji Kishimoto; Hiroshi Honda
Journal:  Radiat Med       Date:  2008-01-31

3.  Novel spirometry based on optical surface imaging.

Authors:  Guang Li; Hailiang Huang; Jie Wei; Diana G Li; Qing Chen; Carl P Gaebler; James Sullivan; Joan Zatcky; Andreas Rimner; James Mechalakos
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

4.  Dosimetric Considerations in Respiratory-Gated Deep Inspiration Breath-Hold for Left Breast Irradiation.

Authors:  Steve Walston; Allison M Quick; Karla Kuhn; Yi Rong
Journal:  Technol Cancer Res Treat       Date:  2016-07-08

5.  Subject-specific real-time respiratory liver motion compensation method for ultrasound-MRI/CT fusion imaging.

Authors:  Minglei Yang; Hui Ding; Jingang Kang; Lei Zhu; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-14       Impact factor: 2.924

Review 6.  Current Therapeutic Approaches to DCIS.

Authors:  Kaleigh Doke; Shirley Butler; Melissa P Mitchell
Journal:  J Mammary Gland Biol Neoplasia       Date:  2018-09-29       Impact factor: 2.673

7.  Cardiac Substructure Segmentation and Dosimetry Using a Novel Hybrid Magnetic Resonance and Computed Tomography Cardiac Atlas.

Authors:  Eric D Morris; Ahmed I Ghanem; Milan V Pantelic; Eleanor M Walker; Xiaoxia Han; Carri K Glide-Hurst
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-11-22       Impact factor: 7.038

8.  Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning.

Authors:  Seyoun Park; Rana Farah; Steven M Shea; Erik Tryggestad; Russell Hales; Junghoon Lee
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

Review 9.  Advances in the use of motion management and image guidance in radiation therapy treatment for lung cancer.

Authors:  Jason K Molitoris; Tejan Diwanji; James W Snider; Sina Mossahebi; Santanu Samanta; Shahed N Badiyan; Charles B Simone; Pranshu Mohindra
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

10.  Variability of Breast Surface Positioning Using an Active Breathing Coordinator for a Deep Inspiration Breath Hold Technique.

Authors:  Kristen McConnell; Neil Kirby; Karl Rasmussen; Alonso N Gutierrez; Nikos Papanikolaou; Dennis Stanley
Journal:  Cureus       Date:  2021-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.