Literature DB >> 12771824

Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants.

Robert Schmidt1, Richard D Komistek, J David Blaha, Brad L Penenberg, William J Maloney.   

Abstract

Contemporary posterior cruciate-retaining total knee designs have provided pain relief and improved knee function but have failed to reproduce the kinematics and stability of the normal nonarthritic knee. The Medial Pivot total knee design features a near constant radius of curvature of the femoral component. The tibial surface is highly congruent and asymmetric, permitting a medial pivot motion during knee flexion. The purpose of the current study was to analyze and compare the gait kinematics of the Sigma posterior cruciate-retaining total knee implant, the Advance Traditional posterior cruciate-retaining total knee implant, and the Advance Medial Pivot knee implant using fluoroscopic analysis. In vivo kinematics were determined for 15 clinically successful total knee arthroplasties. Five knee implants were evaluated from each group. The authors analyzed the kinematics of knee motion during the stance phase of gait for each patient. On average, subjects with the Medial Pivot knee implant had a medial pivot motion. Both posterior cruciateretaining designs had a paradoxical roll forward of the tibia on femur during knee flexion and had greater excursion of both condyles during knee flexion than the medial pivot design. Nine of 10 of the posterior cruciate-retaining designs had condylar lift-off averaging 1.7 mm whereas only one Medial Pivot knee implant had condylar lift-off measuring 1.1 mm.

Entities:  

Mesh:

Year:  2003        PMID: 12771824     DOI: 10.1097/01.blo.0000063565.90853.a4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  42 in total

1.  Internal tibial rotation during in vivo, dynamic activity induces greater sliding of tibio-femoral joint contact on the medial compartment.

Authors:  Yuichi Hoshino; Scott Tashman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-25       Impact factor: 4.342

Review 2.  Medial pivot knee in primary total knee arthroplasty.

Authors:  Francesco Atzori; Wael Salama; Luigi Sabatini; Shazly Mousa; Abdelrahman Khalefa
Journal:  Ann Transl Med       Date:  2016-01

3.  Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

Authors:  James W Pritchett
Journal:  Clin Orthop Relat Res       Date:  2015-02-27       Impact factor: 4.176

4.  The knee joint center of rotation is predominantly on the lateral side during normal walking.

Authors:  Seungbum Koo; Thomas P Andriacchi
Journal:  J Biomech       Date:  2008-03-04       Impact factor: 2.712

5.  In vivo determination of cam-post engagement in fixed and mobile-bearing TKA.

Authors:  Sumesh M Zingde; Filip Leszko; Adrija Sharma; Mohamed R Mahfouz; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

6.  Improved kinematics of total knee replacement following partially navigated modified gap-balancing technique.

Authors:  Clemens Baier; Wolfgang Fitz; Ben Craiovan; Armin Keshmiri; Sebastian Winkler; Robert Springorum; Joachim Grifka; Johannes Beckmann
Journal:  Int Orthop       Date:  2013-10-15       Impact factor: 3.075

7.  Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.

Authors:  Carmen Zietz; Joern Reinders; Jens Schwiesau; Alexander Paulus; Jan Philippe Kretzer; Thomas Grupp; Sandra Utzschneider; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

8.  Comparing navigation-based in vivo knee kinematics pre- and postoperatively between a cruciate-retaining and a cruciate-substituting implant.

Authors:  Clemens Baier; Hans-Robert Springorum; Jürgen Götz; Jens Schaumburger; Christian Lüring; Joachim Grifka; Johannes Beckmann
Journal:  Int Orthop       Date:  2013-01-30       Impact factor: 3.075

9.  Tibiofemoral rotational alignment affects flexion angles in navigated posterior-stabilized total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Akihiko Toda; Shinya Oka; Kazuki Kodato; Koji Takayama; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

10.  No difference between double-high insert and medial-pivot insert in TKA.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Takashi Iwakura; Seiji Kubo; Tetsuhiro Iguchi; Toshihiro Akisue; Kotaro Nishida; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-09       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.