Literature DB >> 12768482

Correlation between femoral neck version and strain on the femur after insertion of femoral prosthesis.

Naoya Umeda1, Masanobu Saito, Nobuhiko Sugano, Kenji Ohzono, Takashi Nishii, Takashi Sakai, Hideki Yoshikawa, Daisaku Ikeda, Atsushi Murakami.   

Abstract

Stress analysis on the femur after insertion of a femoral prosthesis with a modular interchangeable neck with adjustable neck version was performed using in vitro experimental procedures and cemented strain gauges. Although strain on the anterior and posterior aspects was less than on the medial and lateral aspects, it was more markedly affected by adjusting the interchangeable neck from straight to anteverted (or retroverted) than strain on the medial and lateral aspects, particularly around the stem tip. There was a highly significant correlation between compressive strain on the side toward which the prosthetic neck was oriented and the extent of neck version, whether anteverted or retroverted. Insertion of a femoral implant in excessive anteversion (or retroversion) may cause noticeably increased stress on the anterior and posterior aspects of the proximal femoral shaft.

Mesh:

Year:  2003        PMID: 12768482     DOI: 10.1007/s10776-002-0635-2

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  5 in total

1.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

2.  Component version in modular total hip revision.

Authors:  Michael A Kopec; Aaron Pemberton; Joseph C Milbrandt; Gordon Allan
Journal:  Iowa Orthop J       Date:  2009

3.  Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

Authors:  Cs Georgiou; Kg Evangelou; Eg Theodorou; Cg Provatidis; Pd Megas
Journal:  Open Orthop J       Date:  2012-12-14

4.  Changes in strain patterns after implantation of a short stem with metaphyseal anchorage compared to a standard stem: an experimental study in synthetic bone.

Authors:  Jens Gronewold; Sebastian Berner; Gavin Olender; Christof Hurschler; Henning Windhagen; Gabriela von Lewinski; Thilo Floerkemeier
Journal:  Orthop Rev (Pavia)       Date:  2014-03-18

5.  Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation.

Authors:  I Tatani; P Megas; A Panagopoulos; I Diamantakos; Ph Nanopoulos; Sp Pantelakis
Journal:  Biomed Eng Online       Date:  2020-08-19       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.