Literature DB >> 12767419

Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results).

Kevin Wei1, Linda Crouse, James Weiss, Flordeliza Villanueva, Nelson B Schiller, Tasneem Z Naqvi, Robert Siegel, Mark Monaghan, Jonathan Goldman, Paul Aggarwal, Harvey Feigenbaum, Anthony DeMaria.   

Abstract

We hypothesized that assessment of hyperemic myocardial blood flow (MBF) velocity using myocardial contrast echocardiography (MCE) can detect coronary artery disease (CAD). We also postulated that only a single MCE study during stress is required for the detection of CAD in patients with normal function at rest. Patients with known or suspected CAD referred for dipyridamole stress technetium-99m sestamibi single-photon emission computed tomographic (SPECT) studies were enrolled. MCE was performed concurrently with SPECT using continuous infusions of PB127 during intermittent harmonic power Doppler imaging at multiple pulsing intervals. MCE and SPECT were compared in 43 of 54 patients who had adequate studies using both techniques. In 15 of the 43 patients, coronary angiography was performed within 30 days of the MCE/SPECT tests. Overall concordance for classification of patients as normal versus abnormal was 84% (kappa = 0.63) between the 2 tests. When false-negative SPECT scans were corrected for results of angiography, concordance increased to 93% (kappa = 0.82). For territorial analysis, concordance between MCE and SPECT for location of perfusion defects was 65% (kappa = 0.41) and 74% (kappa = 0.61) after SPECT was corrected by angiography. In patients with normal function at rest, a single stress MCE perfusion study allowed identification of CAD with the same concordance as rest/stress perfusion studies. In conclusion, visual assessment of regional differences in MBF velocity using PB127 allows detection of CAD with good concordance compared with technetium-99m sestamibi SPECT. In patients with normal left ventricular function at rest, a single stress PB127 MCE perfusion study is adequate for the detection of CAD.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12767419     DOI: 10.1016/s0002-9149(03)00316-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  18 in total

Review 1.  Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging.

Authors:  C Y Loong; C Anagnostopoulos
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

2.  Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography.

Authors:  Sahar S Abdelmoneim; Mathieu Bernier; Abhijeet Dhoble; Stuart Moir; Mary E Hagen; Sue Ann C Ness; Patricia A Pellikka; Samir S Abdel-Kader; Sharon L Mulvagh
Journal:  Heart Vessels       Date:  2010-03-26       Impact factor: 2.037

Review 3.  Diagnostic and prognostic value of non-invasive imaging in known or suspected coronary artery disease.

Authors:  J D Schuijf; D Poldermans; L J Shaw; J W Jukema; H J Lamb; A de Roos; W Wijns; E E van der Wall; J J Bax
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01       Impact factor: 9.236

Review 4.  Cardiac imaging in coronary artery disease: differing modalities.

Authors:  J D Schuijf; L J Shaw; W Wijns; H J Lamb; D Poldermans; A de Roos; E E van der Wall; J J Bax
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

Review 5.  Assessment of myocardial perfusion with real-time myocardial contrast echocardiography: methodology and clinical applications.

Authors:  Abdou Elhendy; Thomas R Porter
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

Review 6.  Molecular imaging of cardiovascular disease using ultrasound.

Authors:  Flordeliza S Villanueva
Journal:  J Nucl Cardiol       Date:  2008 Jul-Aug       Impact factor: 5.952

7.  Assessment of intravascular and extravascular mechanisms of myocardial perfusion abnormalities in obstructive hypertrophic cardiomyopathy by myocardial contrast echocardiography.

Authors:  Osama I I Soliman; Paul Knaapen; Marcel L Geleijnse; Pieter A Dijkmans; Ashraf M Anwar; Attila Nemes; Michelle Michels; Wim B Vletter; Adriaan A Lammertsma; Folkert J ten Cate
Journal:  Heart       Date:  2007-05-08       Impact factor: 5.994

8.  Ultrasound Detection of Myocardial Ischemic Memory Using an E-Selectin Targeting Peptide Amenable to Human Application.

Authors:  Xiaoping Leng; Jianjun Wang; Andrew Carson; Xucai Chen; Huili Fu; Susanne Ottoboni; William R Wagner; Flordeliza S Villanueva
Journal:  Mol Imaging       Date:  2014-04-01       Impact factor: 4.488

9.  Grey scale enhancement of rabbit liver and kidney by intravenous injection of a new lipid-coated ultrasound contrast agent.

Authors:  Ping Liu; Yun-Hua Gao; Kai-Bin Tan; Zheng Liu; Song Zuo
Journal:  World J Gastroenterol       Date:  2004-08-15       Impact factor: 5.742

10.  Contrast echocardiography in Canada: Canadian Cardiovascular Society/Canadian Society of Echocardiography position paper.

Authors:  George Honos; Robert Amyot; Jonathan Choy; Howard Leong-Poi; Greg Schnell; Eric Yu
Journal:  Can J Cardiol       Date:  2007-04       Impact factor: 5.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.