Abstract

BACKGROUND AND OBJECTIVES: Due to the increased popularity of laryngeal laser therapy, surgeons and anesthesiologists are inevitably confronted with questions concerning the choice of the most efficient endotracheal tube (ETT) for laryngeal laser surgery, especially with regard to possible endolaryngeal tube fires, or combustions. The purpose of this study was to determine the current practice in endolaryngeal laser surgery in Germany. STUDY DESIGN/
MATERIALS AND METHODS: A questionnaire was sent to 152 ENT Departments in Germany, care was taken that the responders could send back the questionnaire anonymously. Among other questions the participants were asked for the number of lasersurgical treatments of the larynx performed in the past, the usual type of ETTs in use, whether other safety precautions were taken during CO2 laser surgery of the larynx and for intraoperative complications like tube ignition, fires or combustions.
RESULTS: Eighty six of the 152 addressed ENT departments replied. In laryngeal laser surgery, 59/86 departments regularly use special laser tubes in daily routine (74.5%). In about 20,000 lasersurgical procedures, 15 incidents of ETT fire have been reported. In six of the reported 15 cases a tube fire occurred despite the fact that special laser tubes had been utilized.
CONCLUSIONS: The present study could demonstrate that the use of special laser tubes does not necessarily protect against ETT fire. Thus, even when using special laser tubes other safety measures should be taken. In view of the maximum safety for the patient it has to be stated, that the safety during surgery correlates definitely with the experience of the surgeon. The weakest point of ETTs is usually situated in the cuff region. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12766961     DOI: 10.1002/lsm.10174

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  9 in total

1.  [Ignition and burning of biological tissue under simulated CO2-laser surgery conditions].

Authors:  O Juri; D Frochaux; G P Rajan; P Biro
Journal:  Anaesthesist       Date:  2006-05       Impact factor: 1.041

2.  Surgery of adult bilateral vocal fold paralysis in adduction: history and trends.

Authors:  Nikolay Sapundzhiev; György Lichtenberger; Hans Edmund Eckel; Gerhard Friedrich; Ivan Zenev; Robert J Toohill; Jochen Alfred Werner
Journal:  Eur Arch Otorhinolaryngol       Date:  2008-04-17       Impact factor: 2.503

3.  Laser safety in head and neck cancer surgery.

Authors:  Ferhan Ahmed; Andrew J Kinshuck; Michael Harrison; Dan O'Brien; Jeffrey Lancaster; Nicholas J Roland; Shaun R Jackson; Terrence M Jones
Journal:  Eur Arch Otorhinolaryngol       Date:  2010-07-21       Impact factor: 2.503

Review 4.  [Anesthetic management in laryngotracheal surgery. High-frequency jet ventilation as strategy for ventilation during general anesthesia].

Authors:  K Fritzsche; A Osmers
Journal:  Anaesthesist       Date:  2010-11       Impact factor: 1.041

5.  [Laser-resistance of a new jet ventilation catheter (LaserJet) under simulated clinical conditions].

Authors:  D Frochaux; G P Rajan; P Biro
Journal:  Anaesthesist       Date:  2004-09       Impact factor: 1.041

Review 6.  Use of lasers in laryngeal surgery.

Authors:  Yan Yan; Aleksandra E Olszewski; Matthew R Hoffman; Peiyun Zhuang; Charles N Ford; Seth H Dailey; Jack J Jiang
Journal:  J Voice       Date:  2009-05-31       Impact factor: 2.009

7.  Hazard of CO₂ laser-induced airway fire in laryngeal surgery: experimental data of contributing factors.

Authors:  Konrad Johannes Stuermer; Stefan Ayachi; Antoniu-O Gostian; Dirk Beutner; Karl-Bernd Hüttenbrink
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-05-01       Impact factor: 2.503

8.  Fire ignition during laser surgery in pet rodents.

Authors:  Tommaso Collarile; Nicola Di Girolamo; Giordano Nardini; Ivano Antonio Ciraci; Paolo Selleri
Journal:  BMC Vet Res       Date:  2012-09-26       Impact factor: 2.741

9.  New Metal Shield for the Endotracheal Tube during Laser Endolaryngeal Surgery.

Authors:  Nasser-Nagieb Mohamed; Mohammad-Waheed El-Anwar
Journal:  Iran J Otorhinolaryngol       Date:  2018-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.