Literature DB >> 12765451

High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control.

Kagari Matsudaira1, Hiroshi Nakagawa, Fred H M Wittkampf, William S Yamanashi, Shinobu Imai, Jan V Pitha, Ralph Lazzara, Warren M Jackman.   

Abstract

The authors hypothesized that during RF ablation, the electrode to tissue interface temperature may significantly exceed electrode temperature in the presence of cooling blood flow and produce thrombus. In 12 anesthetized dogs, the skin over the thigh muscle was incised and raised to form a cradle that was superfused with heparinized canine blood (ACT > 350 s) at 37 degrees C. A 7 Fr, 4-mm or 8-mm ablation electrode containing a thermocouple was held perpendicular to the thigh muscle at 10-g contact weight. Interface temperature was measured at opposite sides of the electrode using tiny optical probes. RF applications (n = 157) were delivered at an electrode temperature of 45 degrees C, 55 degrees C, 65 degrees C, and 75 degrees C for 60 seconds, with or without pulsatile blood flow (150 mL/min). Without blood flow, the interface temperature was similar to the electrode temperature. With blood flow, the interface temperature (side opposite blood flow) was up to 36 degrees C and 57 degrees C higher than the electrode temperature using the 4- and 8-mm electrodes, respectively. After each RF, the cradle was emptied and the electrode and interface were examined. Thrombus developed without impedance rise at an interface temperature as low as 73 degrees C without blood flow and 80 degrees C with blood flow (11/16 RFs at 65 degrees C electrode temperature using 4 mm and 13/13 RFs at an electrode temperature of 55 degrees C using an 8-mm electrode with blood flow). With blood flow, interface temperature markedly exceeded the electrode temperature and the difference was greater with an 8-mm electrode (due to greater electrode cooling). In the presence of blood flow, thrombus occurred without an impedance rise at an electrode temperature as low as 65 degrees C with a 4-mm electrode and 55 degrees C with an 8-mm electrode.

Entities:  

Mesh:

Year:  2003        PMID: 12765451     DOI: 10.1046/j.1460-9592.2003.t01-1-00173.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  14 in total

1.  Open-irrigated laser catheter ablation: influence of catheter irrigation and of contact and noncontact mode of laser application on lesion formation in bovine myocardium.

Authors:  Helmut P Weber; Michaela Sagerer-Gerhardt
Journal:  Lasers Med Sci       Date:  2013-12-11       Impact factor: 3.161

Review 2.  The biophysics of renal sympathetic denervation using radiofrequency energy.

Authors:  Hitesh C Patel; Paramdeep S Dhillon; Felix Mahfoud; Alistair C Lindsay; Carl Hayward; Sabine Ernst; Alexander R Lyon; Stuart D Rosen; Carlo di Mario
Journal:  Clin Res Cardiol       Date:  2014-05       Impact factor: 5.460

3.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Saenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  J Interv Card Electrophysiol       Date:  2020-10       Impact factor: 1.900

4.  Thermal expansion imaging for monitoring lesion depth using M-mode ultrasound during cardiac RF ablation: in vitro study.

Authors:  Peter Baki; Sergio J Sanabria; Gabor Kosa; Gabor Szekely; Orcun Goksel
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

5.  Effect of Charge Delivery on Thromboembolism During Radiofrequency Ablation in Canines.

Authors:  David A Igel; Jon F Urban; James P Kent; Bernard Lim; K L Venkatachalam; Samuel J Asirvatham; Daniel C Sigg
Journal:  JACC Clin Electrophysiol       Date:  2018-05-02

6.  2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias.

Authors:  Edmond M Cronin; Frank M Bogun; Philippe Maury; Petr Peichl; Minglong Chen; Narayanan Namboodiri; Luis Aguinaga; Luiz Roberto Leite; Sana M Al-Khatib; Elad Anter; Antonio Berruezo; David J Callans; Mina K Chung; Phillip Cuculich; Andre d'Avila; Barbara J Deal; Paolo Della Bella; Thomas Deneke; Timm-Michael Dickfeld; Claudio Hadid; Haris M Haqqani; G Neal Kay; Rakesh Latchamsetty; Francis Marchlinski; John M Miller; Akihiko Nogami; Akash R Patel; Rajeev Kumar Pathak; Luis C Sáenz Morales; Pasquale Santangeli; John L Sapp; Andrea Sarkozy; Kyoko Soejima; William G Stevenson; Usha B Tedrow; Wendy S Tzou; Niraj Varma; Katja Zeppenfeld
Journal:  Europace       Date:  2019-08-01       Impact factor: 5.214

7.  Hemostatic changes before and during electrophysiologic study and radiofrequency catheter ablation.

Authors:  Petr Parizek; L Haman; M Pleskot; M Pecka; J Bukac; P Stransky; J Maly
Journal:  Int J Hematol       Date:  2011-03-09       Impact factor: 2.490

8.  Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

Authors:  Ian P Richardson; Rachael Sturtevant; Michael Heung; Michael J Solomon; John G Younger; J Scott VanEpps
Journal:  ASAIO J       Date:  2016 Jan-Feb       Impact factor: 2.872

9.  Should fluid dynamics be included in computer models of RF cardiac ablation by irrigated-tip electrodes?

Authors:  Ana González-Suárez; Juan J Pérez; Enrique Berjano
Journal:  Biomed Eng Online       Date:  2018-04-20       Impact factor: 2.819

10.  Computational Modeling of Open-Irrigated Electrodes for Radiofrequency Cardiac Ablation Including Blood Motion-Saline Flow Interaction.

Authors:  Ana González-Suárez; Enrique Berjano; Jose M Guerra; Luca Gerardo-Giorda
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

View more