Literature DB >> 12763947

Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?

M Whitby1, C J Martin.   

Abstract

The purpose of this study was to ascertain the magnitude and distribution of doses to the legs of radiologists when performing interventional procedures. LiF:Mg,Ti TLD100 chips were used to measure simultaneously doses to the lower limbs and, for comparison, the hands during 100 interventional procedures. Results show leg dose was dependent upon type and complexity of procedure, equipment used and whether lead protection was available. Where no lead protection was used, the doses to the lower limbs were frequently similar to or higher than those received by the hands. The mean dose to the legs ranged from 0.19 mSv to 2.61 mSv per procedure, compared with 0.04 mSv to 1.25 mSv to the hands. During transjugular intrahepatic portosystemic shunt and embolisation procedures the leg dose could be as much as 2-3 times greater than that to the hands. When lead protection was used, the dose to the legs was reduced significantly to 0.02 mSv to 0.5 mSv per procedure. A clear linear relationship was shown between the dose-area product (DAP) reading and the dose to the feet of the radiologist. As a "rule of thumb", a DAP reading of 100 Gy cm(2) will give a dose of 1 mSv to the legs, if no lead protection was used, dropping to approximately 0.02 mSv if lead protection was present. This study demonstrates that the dose to the legs of radiologists can be higher than that to the hands when no lead protection is used. The inclusion of a lead screen to protect the legs is an effective method of dose reduction when performing interventional procedures.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12763947     DOI: 10.1259/bjr/65778215

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  10 in total

1.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

Review 2.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

Review 3.  [Radiation hygiene in medical X-ray imaging: part 2: Assessment of radiation exposure and radiation protection measures].

Authors:  G Brix; R Veit; U Häusler
Journal:  Radiologe       Date:  2010-10       Impact factor: 0.635

Review 4.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

5.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

6.  An investigation of the radiation doses to the lower legs and feet of staff undertaking interventional procedures.

Authors:  R E R Artschan; D S Brettle; K Chase; A Fender; P G Howells; S Buchan
Journal:  Br J Radiol       Date:  2014-03-06       Impact factor: 3.039

7.  Occupational radiation protection in interventional radiology: a joint guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional Radiology.

Authors:  Donald L Miller; Eliseo Vañó; Gabriel Bartal; Stephen Balter; Robert Dixon; Renato Padovani; Beth Schueler; John F Cardella; Thierry de Baère
Journal:  Cardiovasc Intervent Radiol       Date:  2009-12-18       Impact factor: 2.740

8.  Evaluation of Methods of Displaying the Real-Time Scattered Radiation Distribution during Fluoroscopically-Guided Interventions for Staff Dose Reduction.

Authors:  J Kilian-Meneghin; Z Xiong; C Guo; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

Review 9.  Radiation Protection in Interventional Radiology.

Authors:  Tushar Garg; Apurva Shrigiriwar
Journal:  Indian J Radiol Imaging       Date:  2022-01-10

10.  Radiation Protection in Interventional Radiology/Cardiology-Is State-of-the-Art Equipment Used?

Authors:  Christiane Behr-Meenen; Heiner von Boetticher; Jan Felix Kersten; Albert Nienhaus
Journal:  Int J Environ Res Public Health       Date:  2021-12-13       Impact factor: 3.390

  10 in total