Literature DB >> 28565797

Factors affecting the accuracy and safety of computed tomography-guided biopsy of intrapulmonary solitary nodules ≤30 mm in a retrospective study of 155 patients.

Gang Zhao1, Xiaobao Shi2, Wei Sun1, Hongyuan Liang1, Xiaonan Mao1, Feng Wen1, Ming Shan1, Xihai Wang1, Zaiming Lu1.   

Abstract

Computed tomography (CT)-guided percutaneous fine needle biopsy is a common method for lung biopsy. The objective of this study was to investigate factors affecting the accuracy and safety of CT-guided percutaneous lung biopsy of nodules ≤30 mm in diameter. Between January 2013 and March 2014, 155 patients underwent a CT-guided percutaneous biopsy procedure on an intrapulmonary solitary nodule measuring ≤30 mm in diameter. Prospectively collected data were retrospectively reviewed and examined for the influence of clinical and pathological characteristics (age, gender, smoking status, adhesion of nodule to the pleura, puncture depth, nodule size and time of biopsy) on the accuracy of biopsy and incidence of pneumothorax and hemorrhage. The accuracy of CT-guided biopsy was 90.3% (140/155). Biopsies predominantly contained lung adenocarcinoma (114/140; 81.4%) or squamous cell carcinoma of the lung (10/140; 7.1%). Accuracy was significantly dependent on nodule size, ranging in accuracy from 85 to 97% for patients with nodule diameters of ≤20 or 21-30 mm, respectively (P<0.05). Pleural adherence of the nodule significantly increased the accuracy of the biopsy (P<0.05). Patients with a nodule of 11-20 mm in diameter had a significantly higher incidence of pneumothorax compared with patients with a smaller nodule (P=0.013). In conclusion, the nodule size and adhesion to the pleura influenced the accuracy of CT-guided biopsy of intrapulmonary nodules that were ≤30 mm in diameter. Nodule size may also affect the incidence of severe complications. CT-guided percutaneous lung biopsy has a high accuracy and is easy and safe to conduct for intrapulmonary solitary nodules of ≤30 mm in diameter.

Entities:  

Keywords:  accuracy; computed tomography-guidance; hemorrhage; intrapulmonary nodule; lung biopsy; lung puncture; pneumothorax

Year:  2017        PMID: 28565797      PMCID: PMC5443260          DOI: 10.3892/etm.2017.4179

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


  24 in total

1.  The solitary pulmonary nodule on chest radiography: can we really tell if the nodule is calcified?

Authors:  W G Berger; W K Erly; E A Krupinski; J R Standen; R G Stern
Journal:  AJR Am J Roentgenol       Date:  2001-01       Impact factor: 3.959

2.  Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?

Authors:  Takuji Yamagami; Shigeharu Iida; Takeharu Kato; Osamu Tanaka; Tsunehiko Nishimura
Journal:  AJR Am J Roentgenol       Date:  2003-03       Impact factor: 3.959

Review 3.  Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature.

Authors:  Emanuela Capalbo; Michela Peli; Maria Lovisatti; Maria Cosentino; Paola Mariani; Eisabetta Berti; Maurizio Cariati
Journal:  Radiol Med       Date:  2013-12-03       Impact factor: 3.469

4.  Risk factor analysis of pulmonary hemorrhage complicating CT-guided lung biopsy in coaxial and non-coaxial core biopsy techniques in 650 patients.

Authors:  Nour-Eldin A Nour-Eldin; Mohammed Alsubhi; Nagy N Naguib; Thomas Lehnert; Ahmed Emam; Martin Beeres; Boris Bodelle; Karen Koitka; Thomas J Vogl; Volkmar Jacobi
Journal:  Eur J Radiol       Date:  2014-07-05       Impact factor: 3.528

Review 5.  The solitary pulmonary nodule.

Authors:  Helen T Winer-Muram
Journal:  Radiology       Date:  2006-04       Impact factor: 11.105

Review 6.  Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance.

Authors:  Tatjana Boskovic; Jelena Stanic; Slobodanka Pena-Karan; Paul Zarogoulidis; Kostas Drevelegas; Nikolaos Katsikogiannis; Nikolaos Machairiotis; Andreas Mpakas; Kosmas Tsakiridis; Georgios Kesisis; Theodora Tsiouda; Ioanna Kougioumtzi; Stamatis Arikas; Konstantinos Zarogoulidis
Journal:  J Thorac Dis       Date:  2014-03       Impact factor: 2.895

7.  CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan.

Authors:  Noriyuki Tomiyama; Yoshifumi Yasuhara; Yasuo Nakajima; Shuji Adachi; Yasuaki Arai; Masahiko Kusumoto; Kenji Eguchi; Keiko Kuriyama; Fumikazu Sakai; Masayuki Noguchi; Kiyoshi Murata; Sadayuki Murayama; Teruhito Mochizuki; Kiyoshi Mori; Kozo Yamada
Journal:  Eur J Radiol       Date:  2006-03-10       Impact factor: 3.528

8.  C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients.

Authors:  Jin Woo Choi; Chang Min Park; Jin Mo Goo; Yang-Kyun Park; Wonmo Sung; Hyun-Ju Lee; Sang Min Lee; Ji Young Ko; Mi-Suk Shim
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

9.  Transthoracic needle aspiration biopsy of benign and malignant lung lesions.

Authors:  N F Khouri; F P Stitik; Y S Erozan; P K Gupta; W S Kim; W W Scott; U M Hamper; R B Mann; J C Eggleston; R R Baker
Journal:  AJR Am J Roentgenol       Date:  1985-02       Impact factor: 3.959

10.  Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy.

Authors:  M F Khan; R Straub; S R Moghaddam; A Maataoui; J Gurung; T O F Wagner; H Ackermann; A Thalhammer; T J Vogl; V Jacobi
Journal:  Eur Radiol       Date:  2008-03-20       Impact factor: 7.034

View more
  3 in total

1.  Comparison of computed tomography-guided percutaneous needle biopsy and endobronchial biopsy in the diagnosis of multifocal pulmonary lesions.

Authors:  Xiao-Feng Li; Li-Li Zheng; Yu He; Mao-Shui Wang
Journal:  J Clin Lab Anal       Date:  2019-05-10       Impact factor: 2.352

2.  Clinical Implications of "Atypia" on Biopsy: Possible Precursor to Lung Cancer?

Authors:  Denise Albano; Lee Ann Santore; Thomas Bilfinger; Melissa Feraca; Samantha Novotny; Barbara Nemesure
Journal:  Curr Oncol       Date:  2021-07-06       Impact factor: 3.677

3.  Solitary pulmonary nodule: Increasing diagnosis and accuracy of biopsy by biparametric MR imaging.

Authors:  Michele Scialpi; Corrado Maria Malaspina; Valeria Rondoni; Emanuele Orlandi; Luigia Coppola; Teresa Pusiol; Barbara Palumbo
Journal:  Lung India       Date:  2018 Mar-Apr
  3 in total