Literature DB >> 12759635

Two-part and three-part fractures of the proximal humerus treated with suture fixation.

Maxwell C Park1, Anand M Murthi, Neil S Roth, Theodore A Blaine, William N Levine, Louis U Bigliani.   

Abstract

OBJECTIVE: To evaluate the radiographic and clinical outcomes of patients with displaced proximal humerus fractures (two-part and three-part) treated with nonabsorbable rotator cuff-incorporating sutures.
DESIGN: Retrospective.
SETTING: University hospital. PATIENTS: There were 27 patients (28 shoulders) with displaced proximal humerus fractures. There were 13 greater tuberosity (GT) and 9 surgical neck (SN) two-part fractures and 6 GT/SN three-part fractures. The average age was 64 years (range 38 to 84 years). The average follow-up was 4.4 years (range 1.0 to 11.5 years). INTERVENTION: All patients were surgically treated solely with heavy polyester nonabsorbable sutures. MAIN OUTCOME MEASUREMENTS: Functional assessment was obtained using the American Shoulder and Elbow Surgeons (ASES) score and Neer's criteria, which grade outcomes as excellent, satisfactory, or unsatisfactory.
RESULTS: Overall, there were 22 (78%) excellent, 3 (11%) satisfactory, and 3 (11%) unsatisfactory results, and the average ASES score was 87.1 (range 35.0 to 100.0). All shoulders healed radiographically without evidence of avascular necrosis of the humeral head. Twenty-four shoulders (86%) had anatomic alignment on postoperative radiographs. Of four shoulders with nonanatomic alignment, three had ASES scores of >/=90, with excellent Neer scores. When comparing patients with isolated two-part GT fractures (n = 13) with patients having two-part SN or three-part SN/GT fractures (n = 15), there were no statistically significant differences with respect to range of motion (P > 0.05) and outcome measures (P > 0.05). All patients who had unsatisfactory outcomes were noncompliant with physical therapy, with ASES scores averaging 39.4 (range 35.0 to 43.3).
CONCLUSION: Two-part and three-part GT and SN fractures can be treated satisfactorily with heavy nonabsorbable rotator cuff-incorporating sutures, particularly in elderly patients. Hardware-associated complications are obviated. Patients with SN fractures treated with sutures can have outcomes similar to patients with two-part GT fractures. Although the goal is to reconstruct a "one-part" fracture pattern, some residual deformity does not preclude an excellent outcome. A compliant patient is crucial for a successful result.

Entities:  

Mesh:

Year:  2003        PMID: 12759635     DOI: 10.1097/00005131-200305000-00001

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  17 in total

1.  Proximal humerus fractures.

Authors:  Mark J Jo; Michael J Gardner
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

2.  Arthroscopic reduction and fixation for displaced greater tuberosity fractures using the modified suture-bridge technique.

Authors:  RenLong Li; Ming Cai; Kun Tao
Journal:  Int Orthop       Date:  2017-04-11       Impact factor: 3.075

3.  Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus?

Authors:  M A Verdano; E Lunini; A Pellegrini; T Corsini; P Marenghi; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2013-06-08

4.  Strength recovery after proximal humeral fractures treated with locking plate.

Authors:  M A Verdano; P Baudi; A Pellegrini; E Lunini; D Aliani; G Scita; P Schiavi; C Costantino; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2014-03-23

5.  [Management of complications after angularly stable locking proximal humerus plate fixation].

Authors:  C Voigt; A Woltmann; A Partenheimer; H Lill
Journal:  Chirurg       Date:  2007-01       Impact factor: 0.955

6.  Displaced proximal humeral fractures: an Indian experience with locking plates.

Authors:  Sameer Aggarwal; Kamal Bali; Mandeep S Dhillon; Vishal Kumar; Aditya K Mootha
Journal:  J Orthop Surg Res       Date:  2010-08-23       Impact factor: 2.359

7.  The use of locking plates in proximal humeral fractures: Comparison of outcome by patient age and fracture pattern.

Authors:  Michael Leonard; Leibo Mokotedi; Uthman Alao; Aaron Glynn; Mark Dolan; Pat Fleming
Journal:  Int J Shoulder Surg       Date:  2009-10

8.  [Effect of additive fiber cerclage of the rotator cuff in angle-stable plate-stabilized proximal humeral fractures: a biomechanical study of human shoulder specimens].

Authors:  C Voigt; C Hurschler; J Althainz; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2008-07       Impact factor: 1.000

9.  Proximal humeral fractures: an understanding of the ideal plate positioning.

Authors:  Pedro José Labronici; Rodrigo Pires e Albuquerque; Vinícius Schott; Robinson Esteves Santos Pires; Willian Dias Belangero; José Sérgio Franco
Journal:  Int Orthop       Date:  2014-07-20       Impact factor: 3.075

10.  Arthroscopic-assisted plate fixation for displaced large-sized comminuted greater tuberosity fractures of proximal humerus: a novel surgical technique.

Authors:  Sang-Eun Park; Jae-Jung Jeong; Karnav Panchal; Jong-Yun Lee; Hyung-Ki Min; Jong-Hun Ji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-29       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.