Percutaneous renal biopsy by automated biopsy gun.

Aizaz Mand Ahmed1, Muhammad Anees, Amir Riaz, Satwat Mueed.   

Abstract

OBJECTIVE: To study the safety and efficacy of automated biopsy gun in obtaining the renal tissue by percutaneous renal biopsy.
DESIGN: Single centered prospective hospital based study. PLACE AND DURATION OF STUDY: Department of Medicine, Unit II, Lahore General Hospital, Lahore for more than one year from January 2000 to February 2001. SUBJECTS AND METHODS: Forty patients of either gender having clinical features of renal disease with overt proteinuria were included in the study. An informed consent was taken from patients. Patients were lied prone, local anaesthesia was given at lower pole of left kidney. Renal biopsy was performed under ultrasound guidance, using 18G spring loaded automated biopsy gun.
RESULTS: Majority of patients, 28(70%), was male. The mean age was 26.9 years with range of 5-70 years. In 37 (97.5%) patients successful biopsy was done while there was its failure in 3 (7.5%) patients. The average core length of renal tissue obtained was Mean+/-SD (1.02+/-0.34) cm with a mean number of glomeruli per core Mean+/-SD (7.76+/-2.36) and histopathological diagnosis was made in all cases. Total number of attempts were 1-3. In 70% patients single attempt was done. No major complication related to the procedure was seen.
CONCLUSION: Renal biopsy with automated biopsy gun is relatively safe and effective in establishing the diagnosis of renal diseases. Although renal biopsy can be done on outpatient basis, it is better to observe the patients for 24 hours post-operatively for any complication

Entities:  

Mesh:

Year:  2003        PMID: 12757674     DOI: 05.2003/JCPSP.263266

Source DB:  PubMed          Journal:  J Coll Physicians Surg Pak        ISSN: 1022-386X            Impact factor:   0.711


  3 in total

1.  Efficacy and safety of percutaneous renal biopsy performed using 18G needle versus 16G needle: a single-center retrospective study.

Authors:  Senyin Xu; Lili Ma; Jiazhen Lin; Zhengxian Zhang; Xiaoya Wang; Jiazhen Yin
Journal:  Int Urol Nephrol       Date:  2022-07-04       Impact factor: 2.370

2.  A Systematic Review of Complications Associated With Percutaneous Native Kidney Biopsies in Adults in Low- and Middle-Income Countries.

Authors:  Shepherd Kajawo; Udeme Ekrikpo; Mothusi Walter Moloi; Jean Jacques Noubiap; Mohamed A Osman; Ugochi S Okpechi-Samuel; Andre Pascal Kengne; Aminu K Bello; Ikechi G Okpechi
Journal:  Kidney Int Rep       Date:  2020-11-03

3.  Adequacy and complication rates of percutaneous renal biopsy with 18- vs. 16-gauge needles in native kidneys in Chinese individuals.

Authors:  Weiji Xie; Jing Xu; Yi Xie; Zhijun Lin; Xiaochang Xu; Xialan Zhang; Yimin Zhang
Journal:  BMC Nephrol       Date:  2020-08-12       Impact factor: 2.388

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.