Hemodynamic evaluation of normally functioning Sulzer Carbomedics prosthetic valves.

Nurgül Keser1, Navin C Nanda, Andrew P Miller, Szilard Voros, Cahide Soydas, Gopal Agrawal, Chiara Liguori, David Naftel, Albert D Pacifico, James K Kirklin, David C McGiffin, William L Holman.   

Abstract

The Sulzer Carbomedics prosthetic heart valve (CP) is a commonly used mechanical valve in clinical practice. In the present study, we used conventional and color Doppler echocardiography to assess the hemodynamics of normally functioning CP in the aortic (n = 73) and mitral (n = 127) positions. Our findings demonstrate no significant correlation of Doppler-measured peak and mean pressure gradients and effective orifice area with implanted valve size and actual orifice areas, measured directly by the manufacturer for CPs in both the mitral and aortic positions. However, it is still useful to measure effective orifice area by Doppler because a value in the normal or nonstenotic range points to an unobstructed prosthesis in the aortic or mitral position, in the absence of poor left ventricular ejection fraction. A value in the stenotic range could mean a normally functioning or obstructed prosthesis and, therefore, may need further investigation, such as assessment of valve leaflet motion by transthoracic or transesophageal echocardiography or fluoroscopy. Valve regurgitation as evaluated by color Doppler flow mapping was mild in practically all CPs in the aortic position, and in the majority of CPs in the mitral position.

Entities:  

Mesh:

Year:  2003        PMID: 12754064     DOI: 10.1016/s0301-5629(02)00777-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.

Authors:  Denis Bouchard; Frédéric Vanden Eynden; Philippe Demers; Louis P Perrault; Michel Carrier; Raymond Cartier; Arsène J Basmadjian; Michel Pellerin
Journal:  Can J Cardiol       Date:  2010-12       Impact factor: 5.223

Review 2.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

3.  Early outcomes of patient-prosthesis mismatch following aortic valve replacement.

Authors:  Serik Aitaliyev; Egle Rumbinaitė; Karolina Mėlinytė-Ankudavičė; Rokas Nekrošius; Vytenis Keturakis; Rimantas Benetis
Journal:  Perfusion       Date:  2021-06-03       Impact factor: 1.581

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.