Literature DB >> 12750615

Navigator-gated coronary magnetic resonance angiography using steady-state-free-precession: comparison to standard T2-prepared gradient-echo and spiral imaging.

Elmar Spuentrup1, Arno Buecker, Matthias Stuber, Rene Botnar, Trung Hieu Nguyen, Peter Börnert, Christian Kölker, Rolf W Günther.   

Abstract

RATIONALE AND
OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA.
METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared.
RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging.
CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.

Entities:  

Mesh:

Year:  2003        PMID: 12750615     DOI: 10.1097/01.RLI.0000064341.68310.c0

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  12 in total

Review 1.  Coronary magnetic resonance imaging: visualization of the vessel lumen and the vessel wall and molecular imaging of arteriothrombosis.

Authors:  Elmar Spuentrup; Rene M Botnar
Journal:  Eur Radiol       Date:  2005-08-25       Impact factor: 5.315

2.  3D whole-heart coronary MR angiography at 1.5T in healthy volunteers: comparison between unenhanced SSFP and Gd-enhanced FLASH sequences.

Authors:  Hye Mi Gweon; Sang Jin Kim; Sang Min Lee; Yoo Jin Hong; Tae Hoon Kim
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

3.  Optimization of coronary whole-heart MRA free-breathing technique at 3 Tesla.

Authors:  Ahmed M Gharib; Khaled Z Abd-Elmoniem; Daniel A Herzka; Vincent B Ho; Julie Locklin; Efstathia Tzatha; Matthias Stuber; Roderic I Pettigrew
Journal:  Magn Reson Imaging       Date:  2011-08-25       Impact factor: 2.546

4.  Free-breathing 3D steady-state free precession coronary magnetic resonance angiography: comparison of diaphragm and cardiac fat navigators.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

5.  Feasibility and diagnostic accuracy of whole heart coronary MR angiography using free-breathing 3D balanced turbo-field-echo with SENSE and the half-fourier acquisition technique.

Authors:  Young Jin Kim; Jae-Seung Seo; Byoung Wook Choi; Kyu Ok Choe; Yangsoo Jang; Young-Guk Ko
Journal:  Korean J Radiol       Date:  2006 Oct-Dec       Impact factor: 3.500

6.  In vivo quantification of femoral-popliteal compression during isometric thigh contraction: Assessment using MR angiography.

Authors:  Ryan Brown; Thanh D Nguyen; Pascal Spincemaille; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

Review 7.  [Usefulness of cardiovascular magnetic resonance imaging for the detection of coronary artery disease].

Authors:  Robert Manka; Cosima Jahnke; Eckart Fleck; Ingo Paetsch
Journal:  Wien Med Wochenschr       Date:  2008

8.  Coronary artery anomalies and variants: technical feasibility of assessment with coronary MR angiography at 3 T.

Authors:  Ahmed M Gharib; Vincent B Ho; Douglas R Rosing; Daniel A Herzka; Matthias Stuber; Andrew E Arai; Roderic I Pettigrew
Journal:  Radiology       Date:  2008-04       Impact factor: 11.105

9.  Free-breathing 3-dimensional steady-state free precession coronary magnetic resonance angiography: comparison of four navigator gating techniques.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  Magn Reson Imaging       Date:  2009-01-17       Impact factor: 2.546

10.  Non-cardiac findings on coronary computed tomography and magnetic resonance imaging.

Authors:  Marc Dewey; Dirk Schnapauff; Florian Teige; Bernd Hamm
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 7.034

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.