Literature DB >> 12750099

Replacing the Amsler grid: a new method for monitoring patients with age-related macular degeneration.

Anat Loewenstein1, Rafael Malach, Michaela Goldstein, Igal Leibovitch, Adiel Barak, Eli Baruch, Yair Alster, Omer Rafaeli, Isaac Avni, Yuval Yassur.   

Abstract

PURPOSE: To investigate a method that uses hyperacuity, the Macular Computerized Psychophysical Test (MCPT), to evaluate the central macular visual field in patients with age-related macular degeneration (AMD).
DESIGN: Prospective case-control study of a diagnostic test. PARTICIPANTS AND CONTROLS: One hundred eight eyes of 108 Patients with AMD and 51 eyes of 51 age-matched patients with no retinal disease. Patients with AMD included 32 (30%) patients with choroidal neovascularization (CNV), 23 (21%) with geographic atrophy (GA), 35 (32%) with AMD with high-risk characteristics (HRC), and 18 (17%) with early AMD with non-HRC. TESTING: Each subject underwent the MCPT, in which a virtual line composed of dots (white dots on a black background, maximal contrast) is flashed across different macular loci to a perifoveal radius of 7 degrees. Patients' responses were recorded and automatically analyzed using a specific algorithm developed before the onset of the study. All patients also underwent a supervised Amsler grid examination on the encounter before or after the MCPT in random order. MAIN OUTCOME MEASURES: Distortion, scotoma, or blurring perceived by the patient after a swift change of fixation was considered positive on the MCPT. Any perception of distortion, scotoma, or blurring was considered positive on the Amsler grid.
RESULTS: Of the 32 patients with CNV, 30 (94%) were found positive on the MCPT and 11 (34%) were found positive on the Amsler grid. Of the 23 GA patients, 21 (91%) were found positive on the MCPT and 7 (30%) were found positive on the Amsler grid. Of the 35 HRC patients, 28 (80%) were found positive on the MCPT and 3 (9%) were found positive on the Amsler grid, and of the 18 early AMD with non-HRC patients, 8 (44%) were found positive on the MCPT and 3 (17%) were found positive on the Amsler grid. Of the 51 controls, 3 (6%) were positive on the MCPT and 1 (2%) was positive on the Amsler grid.
CONCLUSIONS: The MCPT was superior to the Amsler grid in detecting AMD-related lesions in this cohort. Studies are underway to determine whether the MCPT is feasible for home monitoring to provide early detection of progression to CNV.

Entities:  

Mesh:

Year:  2003        PMID: 12750099     DOI: 10.1016/S0161-6420(03)00074-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  31 in total

1.  The accuracy of home monitoring to detect disease activity during maintenance therapy for neovascular ARMD.

Authors:  Martin McKibbin; Lucy Baker; Paul Baxter; Carolyn Czoski-Muray; Roopa Setty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-05       Impact factor: 3.117

2.  [Smartphones in ophthalmology : Relief or toys for physicians?].

Authors:  B V Stanzel; C H Meyer
Journal:  Ophthalmologe       Date:  2012-01       Impact factor: 1.059

Review 3.  Intrinsic optical signal imaging of retinal physiology: a review.

Authors:  Xincheng Yao; Benquan Wang
Journal:  J Biomed Opt       Date:  2015-09       Impact factor: 3.170

4.  [Anatomical and functional results after elective macular surgery].

Authors:  A Hager; S Ehrich; W Wiegand
Journal:  Ophthalmologe       Date:  2005-06       Impact factor: 1.059

5.  [Diagnostics of metamorphopsia in retinal diseases of different origins].

Authors:  C Klatt; P Sendtner; L Ponomareva; J Hillenkamp; A Bunse; V-P Gabel; J Roider
Journal:  Ophthalmologe       Date:  2006-11       Impact factor: 1.059

Review 6.  The Amsler chart: absence of evidence is not evidence of absence.

Authors:  Michael Crossland; Gary Rubin
Journal:  Br J Ophthalmol       Date:  2007-03       Impact factor: 4.638

7.  Dynamic near-infrared imaging reveals transient phototropic change in retinal rod photoreceptors.

Authors:  Rongwen Lu; Alexander M Levy; Qiuxiang Zhang; Steven J Pittler; Xincheng Yao
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

Review 8.  Diagnostic accuracy of the Amsler grid and the preferential hyperacuity perimetry in the screening of patients with age-related macular degeneration: systematic review and meta-analysis.

Authors:  L Faes; N S Bodmer; L M Bachmann; M A Thiel; M K Schmid
Journal:  Eye (Lond)       Date:  2014-05-02       Impact factor: 3.775

9.  Scanning laser entoptic perimetry for the detection of age-related macular degeneration.

Authors:  William R Freeman; Mohamed El-Bradey; Daniel J Plummer
Journal:  Arch Ophthalmol       Date:  2004-11

10.  Orientation discrimination with macular changes associated with early AMD.

Authors:  Harold E Bedell; Jianliang Tong; Stanley Y Woo; Jon R House; Tammy Nguyen
Journal:  Optom Vis Sci       Date:  2009-05       Impact factor: 1.973

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.