Literature DB >> 12742437

Aspects of water sorption from the air, water and artificial saliva in resin composite restorative materials.

L Musanje1, B W Darvell.   

Abstract

OBJECTIVE: Primarily to establish whether artificial saliva (AS) at 37 degrees C is essential as a clinically relevant environment for testing filled, resin composite restorative materials. The effect of other storage conditions was also investigated for comparison and controls: desiccation, exposure to the laboratory atmosphere, high humidity cabinet, saturated water vapor, and deionized water.
METHODS: Two visible light-cured products were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein). Bar specimens (26 x 1.5 x 1.0 mm(3)) were cured at five overlapping spots for 60s per spot and randomly distributed into groups of six. Trial 1: one group of each material was exposed first to atmospheric air at 24 degrees C, approximately 50% RH (24WV(50)), then to water vapor at 37 degrees C, approximately 97% RH (37WV(97)), and then immersed in deionized water at 37 degrees C (37DW). Trial 2 used three groups of each material, one first exposed to 37WV(97) followed by 37DW, the other two were immediately immersed in 37DW or artificial saliva (37AS). Trial 3: two groups of each material were vacuum desiccated at 37 degrees C, then exposed to 37 degrees C, approximately 100% RH (37WV(100)), then immersed in 37DW or 37AS. Trial 4: four groups of HR were treated similarly to Trial 3; one was left under desiccation, and another in 37WV(100) for the remaining period. Three-point bend tests for flexural strength (F), flexural modulus (E), and total energy to failure (W) were performed at the end of Trials 2-4.
RESULTS: Environmental moisture absorption was substantial at 24WV(50)(c. 0.2%), at least 40% of that in 37DW (HR: c. 0.7%, TC: c. 0.5%). Saturation was achievable in 37WV(100). Mass loss on desiccation (HR: c. 0.4-0.5%, TC: c. 0.25%) was reversible in 37WV(100). There were some significant effects of exposure conditions on mechanical properties (e.g. F for HR: after desiccation, 85.7+/-1.4MPa; after 37WV(100), 73.2+/-3.6MPa; difference: p<0.0002), but overall the results were unclear. After a rapid gain in mass, there was a gradual loss in both 37DW and 37AS for both materials, slightly more in 37AS than 37DW. SIGNIFICANCE: Water vapor absorption is substantial, hence attention must be paid to the laboratory working environment and conditions of storage and testing, i.e. temperature and RH must be stated to assist interpretation of data and comparisons between studies. Test conditions need to be standardized and with reference to normal oral conditions, immediate immersion in artificial saliva at 37 degrees C is the preferred treatment for these materials, whatever time of testing is chosen.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12742437     DOI: 10.1016/s0109-5641(02)00085-4

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  10 in total

1.  The diffusion kinetics of a nanofilled and a midifilled resin composite immersed in distilled water, artificial saliva, and lactic acid.

Authors:  Eduardo Moreira da Silva; Luana Gonçalves; José Guilherme Antunes Guimarães; Laiza Tatiana Poskus; Carlos Eduardo Fellows
Journal:  Clin Oral Investig       Date:  2010-03-09       Impact factor: 3.573

2.  Effectiveness and SEM-EDX analysis following bleaching with an experimental bleaching gel containing titanium dioxide and/or chitosan.

Authors:  Derya Sürmelioğlu; Halime Kolsuz Özçetin; Zeyneb Merve Özdemir; Sevim Atılan Yavuz; Uğur Aydın
Journal:  Odontology       Date:  2020-05-21       Impact factor: 2.634

3.  Surface Characteristics and Color Stability of Dental PEEK Related to Water Saturation and Thermal Cycling.

Authors:  Liliana Porojan; Flavia Roxana Toma; Mihaela Ionela Bîrdeanu; Roxana Diana Vasiliu; Ion-Dragoș Uțu; Anamaria Matichescu
Journal:  Polymers (Basel)       Date:  2022-05-25       Impact factor: 4.967

4.  Discoloration of PMMA, composite, and PEEK.

Authors:  Sina Heimer; Patrick R Schmidlin; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2016-06-25       Impact factor: 3.573

5.  Surface Morphology and Tooth Adhesion of a Novel Nanostructured Dental Restorative Composite.

Authors:  Marco Salerno; Patrizia Loria; Giunio Matarazzo; Francesco Tomè; Alberto Diaspro; Roberto Eggenhöffner
Journal:  Materials (Basel)       Date:  2016-03-16       Impact factor: 3.623

6.  A New Customized Bioactive Glass Filler to Functionalize Resin Composites: Acid-Neutralizing Capability, Degree of Conversion, and Apatite Precipitation.

Authors:  Matej Par; Thomas Attin; Zrinka Tarle; Tobias T Tauböck
Journal:  J Clin Med       Date:  2020-04-19       Impact factor: 4.241

7.  Evaluation of the Behavior of Two CAD/CAM Fiber-Reinforced Composite Dental Materials by Immersion Tests.

Authors:  Farah Bechir; Simona Maria Bataga; Adrian Tohati; Elena Ungureanu; Cosmin Mihai Cotrut; Edwin Sever Bechir; Mircea Suciu; Diana Maria Vranceanu
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

8.  Evaluation of shear bond strength of various adhesives under Simulated intrapulpal pressure: An in vitro study.

Authors:  Sreelakshmi Pradeep; Neeta Shetty; Ravindra Kotian; Ramya Shenoy; Ishani Saluja
Journal:  J Conserv Dent       Date:  2021-10-09

9.  Changes in water sorption and solubility of dental adhesive systems after cigarette smoke.

Authors:  Lívia Andrade Vitória; Thaiane Rodrigues Aguiar; Poliana Ramos Braga Santos; Andrea Nóbrega Cavalcanti; Paula Mathias
Journal:  ISRN Dent       Date:  2013-07-28

10.  Solubility of two resin composites in different mouthrinses.

Authors:  Sezin Ozer; Emine Sen Tunc; Nuray Tuloglu; Sule Bayrak
Journal:  Biomed Res Int       Date:  2014-04-07       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.