Monitoring of intramuscular pressure.

F A Matsen, K A Mayo, G W Sheridan, R B Krugmire.   

Abstract

Increased pressure within an osteofascial compartment may produce a compartmental syndrome, one of the principal causes of local circulatory compromise in traumatized extremities. In certain instances, monitoring of intracompartmental pressure may be a valuable adjunct in the clinical evaluation of patients at risk for this syndrome.

Entities:  

Mesh:

Year:  1976        PMID: 1273755

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  25 in total

1.  Compartment syndrome of the arm: a complication of noninvasive blood pressure monitoring during thrombolytic therapy for myocardial infarction.

Authors:  J Winslow Alford; Mark A Palumbo; Michael J Barnum
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

2.  Intramuscular pressures during exercise: an evaluation of a fiber optic transducer-tipped catheter system.

Authors:  A G Crenshaw; J R Styf; A R Hargens
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

3.  Effect of vacuum sealing drainage in osteofascial compartment syndrome.

Authors:  Weihua Li; Lei Ji; Weidong Tao
Journal:  Int J Clin Exp Med       Date:  2015-09-15

4.  Evaluation of a fiber-optic technique for recording intramuscular pressure in the human leg.

Authors:  Andreas Nilsson; Qiuxia Zhang; Jorma Styf
Journal:  J Clin Monit Comput       Date:  2015-08-14       Impact factor: 2.502

5.  Normal leg compartment pressures in adult Nigerians using the Whitesides method.

Authors:  Johnson D Ogunlusi; Lawrence M Oginni; Innocent C Ikem
Journal:  Iowa Orthop J       Date:  2005

Review 6.  [Vacuum-assisted closure therapy and wound coverage in soft tissue injury. Clinical use].

Authors:  G Holle; G Germann; M Sauerbier; K Riedel; H von Gregory; M Pelzer
Journal:  Unfallchirurg       Date:  2007-04       Impact factor: 1.000

7.  Design Considerations of a Fiber Optic Pressure Sensor Protective Housing for Intramuscular Pressure Measurements.

Authors:  Shanette A Go; Elisabeth R Jensen; Shawn M O'Connor; Loribeth Q Evertz; Duane A Morrow; Samuel R Ward; Richard L Lieber; Kenton R Kaufman
Journal:  Ann Biomed Eng       Date:  2016-08-05       Impact factor: 3.934

8.  [Blood pressure-dependent, process-controlled hemostasis to minimize tourniquet syndrome].

Authors:  E Egkher; R Freund; U Kroitzsch; B Wielke
Journal:  Unfallchirurgie       Date:  1986-08

9.  The relation between spectral changes of the myoelectric signal and the intramuscular pressure of human skeletal muscle.

Authors:  L Körner; P Parker; C Almström; P Herberts; R Kadefors
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1984

10.  Anterior compartment pressure measurement in closed fractures of leg.

Authors:  K C Saikia; T D Bhattacharya; V Agarwala
Journal:  Indian J Orthop       Date:  2008-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.