Literature DB >> 12731096

Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: a feasibility study.

Ofer Ron1, Leo Joskowicz, Charles Milgrom, Ariel Simkin.   

Abstract

A new computer-based method for measuring periaxial rotation of healthy and fractured femurs from preoperative CT during closed femoral fracture reduction surgery is described. The method provides a comparative quantitative measure to align the distal and proximal femur fragments based on periaxial rotation. The periaxial rotation is defined in terms of patient-specific bone features. An algorithm for automatically extracting these features from the CT based on this definition has been developed. The algorithm extracts the condyle landmarks and neck axis of the healthy bone, determines its periaxial rotation, and extrapolates this data, assuming mirror symmetry between the healthy and fractured bones, to measure periaxial rotation between the fractured fragments. Unlike existing techniques, the method requires minimal user intervention. In a feasibility study, the method was applied to five dry femurs and one patient data set, and simulated a reduction based on the periaxial measurements with satisfactory results. The experiments showed the measured angle on the fractured femur to be within 1-4.5 degrees of that of the healthy bone. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12731096     DOI: 10.1002/igs.10056

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  6 in total

1.  A computational/experimental platform for investigating three-dimensional puzzle solving of comminuted articular fractures.

Authors:  Thaddeus P Thomas; Donald D Anderson; Andrew R Willis; Pengcheng Liu; Matthew C Frank; J Lawrence Marsh; Thomas D Brown
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-03       Impact factor: 1.763

2.  Computer-assisted fracture reduction: a new approach for repositioning femoral fractures and planning reduction paths.

Authors:  Jan Buschbaum; Rainer Fremd; Tim Pohlemann; Alexander Kristen
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-10       Impact factor: 2.924

3.  [Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis].

Authors:  D G Maier; R Reisig; P Keppler; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2005-02       Impact factor: 1.000

4.  Design and evaluation of an intelligent reduction robot system for the minimally invasive reduction in pelvic fractures.

Authors:  Chunpeng Zhao; Yu Wang; Xinbao Wu; Gang Zhu; Shuchang Shi
Journal:  J Orthop Surg Res       Date:  2022-04-04       Impact factor: 2.359

5.  3D atlas-based registration can calculate malalignment of femoral shaft fractures in six degrees of freedom.

Authors:  Meghan C Crookshank; Maarten Beek; Michael R Hardisty; Emil H Schemitsch; Cari M Whyne
Journal:  Comput Aided Surg       Date:  2014-04-10

6.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.