Literature DB >> 12729111

A femoral component with proximal HA coating. An analysis of survival and fixation at up to ten years.

J A Skinner1, P O Kroon, S Todo, G Scott.   

Abstract

We describe the survival at ten years of 100 femoral components of the Freeman hip prosthesis. It is proximally hydroxyapatite (HA)-coated and was fixed without cement. Radiological assessment identified radiolucent lines (RLLs) and lytic lesions and was used to measure migration. The criterion of failure was revision or impending revision for aseptic femoral loosening. No femoral components were revised or are awaiting revision for aseptic loosening, giving 100% survival at ten years (95% confidence interval, 95.7 to 100), although 59 were at risk at ten years. Two components were revised for fracture of a ceramic head with damage to the trunnion. Although well fixed in each, for survival analysis we evaluated the hip as if the patient had died. Twelve acetabular components were revised and at each operation the femoral component was found to be well fixed, was not disturbed and remained in the survival analysis. Three patients were lost to follow-up, and 12 died with well-functioning prostheses. Radiologically, all except one of the components appeared to be well fixed with no RLLs and no lytic lesions at the latest follow-up. The mean vertical migration was 0.4 mm at one year, 0.8 mm at two years and 1.4 mm at ten years. One component had migrated 7.6 mm at ten years (2.1 mm in year 1) and developed RLLs in Gruen zones I and II. The symptoms, however, were only minor and revision was not indicated. Our study has shown that proximal HA coating gives effective fixation for a femoral component.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12729111     DOI: 10.1302/0301-620x.85b3.13054

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Neck-preserving femoral stems.

Authors:  Karthig Rajakulendran; Richard E Field
Journal:  HSS J       Date:  2012-09-07

2.  Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty.

Authors:  Jin-Ho Cho; Jonathan P Garino; Suk-Kyu Choo; Kye-Young Han; Jung-Hoon Kim; Hyoung-Keun Oh
Journal:  Clin Orthop Surg       Date:  2010-11-05

3.  Uncemented fully hydroxyapatite-coated hip stem for intracapsular femoral neck fractures in osteoporotic elderly patients: a multicenter study.

Authors:  Fabrizio Rivera; Francesco Leonardi; Pietro Maniscalco; Marco Caforio; Roberto Capelli; Giampaolo Molinari; Paolo Esopi
Journal:  Arthroplast Today       Date:  2015-08-28

Review 4.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

5.  Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability: a randomized controlled RSA study with 5-year follow-up.

Authors:  Erik Weber; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2014-09-01       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.