| Literature DB >> 12723785 |
Armand De Clercq1, Geert Crombez, Ann Buysse, Herbert Roeyers.
Abstract
Timing accuracy in presenting experimental stimuli (visual information on a PC or on a TV) and responding (keyboard presses and mouse signals) is of importance in several experimental paradigms. In this article, a simple system for measuring timing accuracy is described. The system uses two PCs (at least Pentium II, 200 MHz), a photocell, and an amplifier. No additional boards and timing hardware are needed. The first PC, a SlavePC, monitors the keyboard presses or mouse signals from the PC under test and uses a photocell that is placed in front of the screen to detect the appearance of visual stimuli on the display. The software consists of a small program running on the SlavePC. The SlavePC is connected through a serial line with a second PC. This MasterPC controls the SlavePC through an ActiveX control, which is used in a Visual Basic program. The accuracy of our system was investigated by using a similar setup of a SlavePC and a MasterPC to generate pulses and by using a pulse generator card. These tests revealed that our system has a 0.01-msec accuracy. As an illustration, the reaction time accuracy of INQUISIT for a few applications was tested using our system. It was found that in those applications that we investigated, INQUISIT measures reaction times from keyboard presses with millisecond accuracy.Entities:
Mesh:
Year: 2003 PMID: 12723785 DOI: 10.3758/bf03195502
Source DB: PubMed Journal: Behav Res Methods Instrum Comput ISSN: 0743-3808