Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data?

Daniele Giansanti1, Velio Macellari, Giovanni Maccioni, Aurelio Cappozzo.   

Abstract

The analysis of the mechanics of the musculo-skeletal system during the execution of a motor task requires the determination of the instantaneous position and orientation of the body segments involved in relation to an inertial system of reference. By using adequately assembled uniaxial accelerometric sensors, an easy-to-manage measurement system can be obtained that estimates the three-dimensional position and orientation (P&O) of a body segment through an appropriate analytical model. However, the extent to which experimental errors, in particular accelerometers (ACs) assembly inaccuracies, affect such estimation has never been systematically investigated. This paper systematically analyzes the sensitivity of analytical models of body segment P&O reconstruction through a six-AC system and a nine-AC system to different sources of experimental error. We simulated and statistically assessed the performance of these models in the case of body segment motions typical of movements under muscular control. The results obtained indicated that the inaccuracy in the orientation of the individual AC's active axes and the offset error in the AC responses were the major sources of P&O estimation errors. In particular, no accurate estimation of position was possible with the analytical models analyzed. Under the motion conditions simulated in this study, no substantial advantages were found in using a nine-AC system rather than a six-AC system. Considering that the magnitudes of the simulated experimental errors were quite low (< or = 0.1 deg: AC's orientation; < or = 10(-4) m: uncertainty of the distance between two ACs; < or = 10(-2) ms(-2): random error; 0.5 x 10(-2) ms(-2): offset error), the results indicate that none of the two ACs systems analyzed is suitable for body segment P&O estimation in routine biomechanical applications.

Mesh:

Year:  2003        PMID: 12723059     DOI: 10.1109/TBME.2003.809490

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  8 in total

1.  A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries.

Authors:  J Favre; F Luthi; B M Jolles; O Siegrist; B Najafi; K Aminian
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-01-19       Impact factor: 4.342

2.  Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects.

Authors:  Daniele Giansanti; Giovanni Maccioni; Francesco Benvenuti; Velio Macellari
Journal:  Med Biol Eng Comput       Date:  2007-07-25       Impact factor: 2.602

3.  The mHealth in the canine assisted therapy: the design and application of a kit for the wearable monitoring during a walking session.

Authors:  Daniele Giansanti; Giovanni Maccioni
Journal:  Mhealth       Date:  2020-04-05

Review 4.  Estimating three-dimensional orientation of human body parts by inertial/magnetic sensing.

Authors:  Angelo Maria Sabatini
Journal:  Sensors (Basel)       Date:  2011-01-26       Impact factor: 3.576

5.  State derivation of a 12-axis gyroscope-free inertial measurement unit.

Authors:  Jau-Ching Lu; Pei-Chun Lin
Journal:  Sensors (Basel)       Date:  2011-03-14       Impact factor: 3.576

6.  Advances in wearable technology and applications in physical medicine and rehabilitation.

Authors:  Paolo Bonato
Journal:  J Neuroeng Rehabil       Date:  2005-02-25       Impact factor: 4.262

7.  A sensor fusion method for tracking vertical velocity and height based on inertial and barometric altimeter measurements.

Authors:  Angelo Maria Sabatini; Vincenzo Genovese
Journal:  Sensors (Basel)       Date:  2014-07-24       Impact factor: 3.576

8.  Ecological inference using data from accelerometers needs careful protocols.

Authors:  Baptiste Garde; Rory P Wilson; Adam Fell; Nik Cole; Vikash Tatayah; Mark D Holton; Kayleigh A R Rose; Richard S Metcalfe; Hermina Robotka; Martin Wikelski; Fred Tremblay; Shannon Whelan; Kyle H Elliott; Emily L C Shepard
Journal:  Methods Ecol Evol       Date:  2022-02-07       Impact factor: 8.335

  8 in total