Literature DB >> 12719053

Hemodynamic and catecholamine response to tracheal intubation: direct laryngoscopy compared with fiberoptic intubation.

Michal Barak1, Avishai Ziser, Avital Greenberg, Sophie Lischinsky, Beno Rosenberg.   

Abstract

STUDY
OBJECTIVE: To compare the stress response following tracheal intubation using direct laryngoscopy to that using fiberoptic bronchoscopy technique.
DESIGN: Randomized, prospective study.
SETTING: Operating rooms in a teaching hospital. PATIENTS: 51 ASA physical status I and II patients who were scheduled for an elective surgery with general anesthesia.
INTERVENTIONS: Patients were randomly assigned to receive either direct laryngoscopy or fiberoptic orotracheal intubation, as part of general anesthesia. A uniform protocol of anesthetic medications was used. MEASUREMENTS: Blood pressure and heart rate were measured before induction, before endotracheal intubation, and 1, 2, 3, and 5 minutes afterwards. Catecholamine (epinephrine and norepinephrine) blood samples were drawn before the induction, and 1 and 5 minutes after intubation. MAIN
RESULTS: Duration of intubation was shorter in the direct laryngoscopy group (16.9 (16.9 +/- 7.0 sec, range 8 to 40) compared with the fiberoptic intubation group (55.0 +/- 22.5 sec, range 29 to 120), p < 0.0,001. In both groups, blood pressure and heart rate were significantly increased at 1, 2, and 3 minutes after intubation, but there was no significant difference between the two study groups. Catecholamine levels did not increase after intubation and did not correlate with the hemodynamic changes.
CONCLUSIONS: The use of either direct laryngoscopy or fiberoptic bronchoscopy produces a comparable stress response to tracheal intubation. Catecholamine levels do not correlate with the hemodynamic changes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12719053     DOI: 10.1016/s0952-8180(02)00514-7

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  17 in total

1.  Comparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia.

Authors:  Huseyin Toman; Mesut Erbas; Hasan Sahin; Hasan Ali Kiraz; Metehan Uzun; Mehmet Akif Ovali
Journal:  J Clin Monit Comput       Date:  2015-01-31       Impact factor: 2.502

2.  Effects of esmolol, lidocaine and fentanyl on haemodynamic responses to endotracheal intubation: a comparative study.

Authors:  Bakiye Ugur; Mustafa Ogurlu; Erdal Gezer; Osman Nuri Aydin; Feray Gürsoy
Journal:  Clin Drug Investig       Date:  2007       Impact factor: 2.859

3.  Perfusion index versus non-invasive hemodynamic parameters during insertion of i-gel, classic laryngeal mask airway and endotracheal tube.

Authors:  Hosam M Atef; Salah Abd Fattah; Mohammed Emad Abd Gaffer; Ahamed Abd Al Rahman
Journal:  Indian J Anaesth       Date:  2013-03

4.  Attenuation of the haemodynamic responses to tracheal intubation with gabapentin, fentanyl and a combination of both: A randomised controlled trial.

Authors:  Satyen Parida; Niyaz Channanath Ashraf; Jibin Sam Mathew; Sandeep Kumar Mishra; Ashok Shankar Badhe
Journal:  Indian J Anaesth       Date:  2015-05

5.  Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

Authors:  Nitesh Gill; Shobha Purohit; Poonam Kalra; Tarun Lall; Avneesh Khare
Journal:  Anesth Essays Res       Date:  2015 Sep-Dec

6.  The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography.

Authors:  Pekka Talke
Journal:  Anesthesiol Res Pract       Date:  2017-04-02

7.  Haemodynamic Response to Four Different Laryngoscopes.

Authors:  Demet Altun; Achmet Ali; Emre Çamcı; Anıl Özonur; Tülay Özkan Seyhan
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-09-06

8.  The Pentax airway scope versus the Macintosh laryngoscope: Comparison of hemodynamic responses and concentrations of plasma norepinephrine to tracheal intubation.

Authors:  Heeseung Lee
Journal:  Korean J Anesthesiol       Date:  2013-04-22

9.  Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope.

Authors:  Kapil Gupta; Kiran Kumar Girdhar; Raktima Anand; Sumanth Mallikarjuna Majgi; Surinder Pal Gupta; Payal Bansal Gupta
Journal:  Indian J Anaesth       Date:  2012-07

10.  A study of stress response to endotracheal intubation comparing glidescope and flexible fiberoptic bronchoscope.

Authors:  Mansoor Aqil
Journal:  Pak J Med Sci       Date:  2014-09       Impact factor: 1.088

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.