Literature DB >> 12714144

Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound.

Muzaffer Degertekin1, Evelyn Regar, Kengo Tanabe, Pedro Lemos, Chi Hang Lee, Peter Smits, Pim de Feyter, Niko Bruining, Eduardo Sousa, Alexandre Abizaid, Jurgen Ligthart, Patrick W Serruys.   

Abstract

This study evaluates the response of the coronary vessel wall to implantation of the sirolimus-eluting stent (SES), Bx-VELOCITY, by using serial intravascular ultrasound. SESs have a major impact on the inhibition of in-stent neointimal hyperplasia. However, changes in the vessel wall and behind stent struts in animal models and humans have not been evaluated after SES implantation. Thirty-four patients who received a SES (n = 24) or a Bx-VELOCITY bare stent (BS) (n = 10) for single de novo coronary lesions and had serial motorized pullback 3-dimensional intravascular ultrasound were included. Stent, lumen, and vessel volumes were similar in the 2 groups at baseline. At follow-up, significantly larger lumen and lower neointimal hyperplasia volumes (0.7 vs 33 mm(3), p = 0.001) were seen in the SES group compared with the BS group. There was no significant difference between SES and BS in either the vessel volume (+2.4% vs +0.7%, p = NS) or the plaque behind stent volume change (+3.4% vs +2.5%, p = NS) from after the procedure to late follow-up. The stent edges also showed no significant difference between postprocedural and follow-up measurements, either in patients receiving SESs or BSs. No stented or edge segment required redilatation in the SES group, whereas 2 patients underwent repeat percutaneous coronary angioplasty in the BS group. In the SES group, 1 patient (4%) showed late acquired incomplete stent apposition. Thus, the SES is effective in inhibiting neointimal hyperplasia without affecting vessel volume and plaque behind the stent.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12714144     DOI: 10.1016/s0002-9149(03)00146-2

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Current problems and potential techniques in in vivo glucose monitoring.

Authors:  Y Wickramasinghe; Y Yang; S A Spencer
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

2.  Comparison of intravascular ultrasonic imaging with versus without incomplete stent apposition at follow-up after drug-eluting stent implantation.

Authors:  Juying Qian; Feng Zhang; Hongyi Wu; Bing Fan; Lei Ge; Junbo Ge
Journal:  Int J Cardiovasc Imaging       Date:  2007-08-17       Impact factor: 2.357

Review 3.  [When are drug-eluting stents effective? A critical analysis of the presently available data].

Authors:  S Silber
Journal:  Z Kardiol       Date:  2004-09

4.  Comparison of sirolimus and paclitaxel-eluting stents for complex coronary lesions: an intravascular ultrasound study.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur; Hyun-Tae Kim; In-Cheol Kim; Hyoung-Seob Park; Hyuck-Jun Yoon; Chang-Wook Nam; Hyungseop Kim; Seong-Wook Han; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean J Intern Med       Date:  2009-11-27       Impact factor: 2.884

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.