Abstract

The motion of the carotid atheromatous plaque relative to the adjacent wall may be related to the risk of cerebral events. A quantitative method for motion estimation was applied to analyse arterial wall movement from sequences of 2-D B-mode ultrasound (US) images. Image speckle patterns were tracked between successive frames using the correlation coefficient as the matching criterion. The size of the selected region-of-interest (ROI) was shown to affect the motion analysis results; an optimal size of 3.2 x 2.5 mm(2) was suggested for tracking a region at the wall-lumen interface and of 6.3 x 2.5 mm(2) for one within the tissue. The results showed expected cyclical motion in the radial direction and some axial movement of the arterial wall. The method can be used to study further the axial motion of the carotid artery wall and plaque and, thus, provide useful insight into the mechanisms of atherosclerosis.

Entities:  

Mesh:

Year:  2003        PMID: 12706190     DOI: 10.1016/s0301-5629(02)00760-3

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  25 in total

1.  A mathematical model for estimating the axial stress of the common carotid artery wall from ultrasound images.

Authors:  Effat Soleimani; Manijhe Mokhtari-Dizaji; Hajir Saberi; Shervin Sharif-Kashani
Journal:  Med Biol Eng Comput       Date:  2015-11-13       Impact factor: 2.602

2.  3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy.

Authors:  Cristiana Corsi; Corrado Tomasi; Dario Turco; Massimo Margheri; Claudio Lamberti; Stefano Severi
Journal:  Med Biol Eng Comput       Date:  2011-06-29       Impact factor: 2.602

3.  Ultrasound-based liver tracking utilizing a hybrid template/optical flow approach.

Authors:  Tom Williamson; Wa Cheung; Stuart K Roberts; Sunita Chauhan
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-06-05       Impact factor: 2.924

Review 4.  Recent developments in vascular ultrasound technology.

Authors:  P R Hoskins; D A Kenwright
Journal:  Ultrasound       Date:  2015-03-26

5.  In vitro experiment using porcine artery for evaluation of ultrasonic measurement of arterial luminal surface profile.

Authors:  Yoshifumi Nagai; Magnus Cinthio; Hideyuki Hasegawa; Martin Bengtsson; Mikael Evander; John Albinsson; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2014-05-07       Impact factor: 1.314

6.  A semiautomatic method for in vivo three-dimensional quantitative analysis of fascial layers mobility based on 3D ultrasound scans.

Authors:  S Condino; G Turini; S Parrini; A Stecco; F Busoni; V Ferrari; M Ferrari; M Gesi
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-03-06       Impact factor: 2.924

7.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

8.  Repeated Loading Behavior of Pediatric Porcine Common Carotid Arteries.

Authors:  Stephanie A Pasquesi; Yishan Liu; Susan S Margulies
Journal:  J Biomech Eng       Date:  2016-12-01       Impact factor: 2.097

9.  Carotid artery distensibility: a reliability study.

Authors:  Elisa Cuadrado Godia; Rishi Madhok; John Pittman; Samuel Trocio; Romel Ramas; Digna Cabral; Ralph L Sacco; Tatjana Rundek
Journal:  J Ultrasound Med       Date:  2007-09       Impact factor: 2.153

10.  Wave intensity wall analysis: a novel noninvasive method to measure wave intensity.

Authors:  Matilda Larsson; Anna Bjällmark; Britta Lind; Rita Balzano; Michael Peolsson; Reidar Winter; Lars-Ake Brodin
Journal:  Heart Vessels       Date:  2009-09-27       Impact factor: 2.037

View more