Literature DB >> 12701897

Performance characteristics of the MIT fission converter based epithermal neutron beam.

K J Riley1, P J Binns, O K Harling.   

Abstract

A pre-clinical characterization of the first fission converter based epithermal neutron beam (FCB) designed for boron neutron capture therapy (BNCT) has been performed. Calculated design parameters describing the physical performance of the aluminium and Teflon filtered beam were confirmed from neutron fluence and absorbed dose rate measurements performed with activation foils and paired ionization chambers. The facility currently provides an epithermal neutron flux of 4.6 x 10(9) n cm(-2) s(-1) in-air at the patient position that makes it the most intense BNCT source in the world. This epithermal neutron flux is accompanied by very low specific photon and fast neutron absorbed doses of 3.5 +/- 0.5 and 1.4 +/- 0.2 x 10(-13) Gy cm2, respectively. A therapeutic dose rate of 1.7 RBE Gy min(-1) is achievable at the advantage depth of 97 mm when boronated phenylalanine (BPA) is used as the delivery agent, giving an average therapeutic ratio of 5.7. In clinical trials of normal tissue tolerance when using the FCB, the effective prescribed dose is due principally to neutron interactions with the nonselectively absorbed BPA present in brain. If an advanced compound is considered, the dose to brain would instead be predominately from the photon kerma induced by thermal neutron capture in hydrogen and advantage parameters of 0.88 Gy min(-1), 121 mm and 10.8 would be realized for the therapeutic dose rate, advantage depth and therapeutic ratio, respectively. This study confirms the success of a new approach to producing a high intensity, high purity epithermal neutron source that attains near optimal physical performance and which is well suited to exploit the next generation of boron delivery agents.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12701897     DOI: 10.1088/0031-9155/48/7/310

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Intracavitary moderator balloon combined with (252)Cf brachytherapy and boron neutron capture therapy, improving dosimetry in brain tumour and infiltrations.

Authors:  S F Brandão; T P R Campos
Journal:  Br J Radiol       Date:  2015-04-30       Impact factor: 3.039

2.  Selective irradiation of the vascular endothelium has no effect on the survival of murine intestinal crypt stem cells.

Authors:  Bradley W Schuller; Peter J Binns; Kent J Riley; Ling Ma; M Frederick Hawthorne; Jeffrey A Coderre
Journal:  Proc Natl Acad Sci U S A       Date:  2006-02-27       Impact factor: 11.205

3.  Mechanistic Modeling of the Relative Biological Effectiveness of Boron Neutron Capture Therapy.

Authors:  Seth W Streitmatter; Robert D Stewart; Gregory Moffitt; Tatjana Jevremovic
Journal:  Cells       Date:  2020-10-15       Impact factor: 6.600

Review 4.  Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer.

Authors:  Rolf F Barth; M Graca H Vicente; Otto K Harling; W S Kiger; Kent J Riley; Peter J Binns; Franz M Wagner; Minoru Suzuki; Teruhito Aihara; Itsuro Kato; Shinji Kawabata
Journal:  Radiat Oncol       Date:  2012-08-29       Impact factor: 3.481

5.  Development of an integrated Monte Carlo model for glioblastoma multiforme treated with boron neutron capture therapy.

Authors:  Leyla Moghaddasi; Eva Bezak
Journal:  Sci Rep       Date:  2017-08-01       Impact factor: 4.379

  5 in total