Literature DB >> 12695197

T1-weighted fluid-attenuated inversion recovery at low field strength: a viable alternative for T1-weighted intracranial imaging.

Masaaki Hori1, Toshiyuki Okubo, Kazuhito Uozumi, Keiichi Ishigame, Hiroshi Kumagai, Tsutomu Araki.   

Abstract

BACKGROUND AND
PURPOSE: T1-weighted spin-echo imaging has been widely used to study anatomic detail and abnormalities of the brain; however, the image contrast of this technique is often poor, especially at low field strengths. We tested a new pulse sequence, T1-weighted fluid-attenuated inversion recovery (FLAIR), which provides good contrast between lesions, surrounding edematous tissue, and normal parenchyma at low field strengths and at acquisition times comparable to those of T1-weighted spin-echo imaging.
METHODS: Thirteen patients with brain lesions underwent T1-weighted spin-echo and T1-weighted FLAIR imaging during the same imaging session. T1-weighted spin-echo and T1-weighted FLAIR images were compared on the basis of four quantitative (lesion-white matter [WM] contrast-to-noise ratio [CNR], lesion-CSF CNR, gray matter-WM CNR, and WM-CSF CNR) and three qualitative criteria (conspicuousness of lesions, image artifacts, and overall image contrast).
RESULTS: CNRs obtained with T1-weighted FLAIR were comparable but statistically superior to those obtained with T1-weighted spin-echo imaging. In general, T1-weighted FLAIR and T1-weighted spin-echo imaging produced comparable image artifacts. Conspicuousness of lesions and the overall image contrast were judged to be superior on T1-weighted FLAIR images.
CONCLUSION: T1-weighted FLAIR imaging may be a valuable alternative to conventional T1-weighted imaging, because the former technique offers superior image contrast at low field strengths and comparable acquisition times.

Entities:  

Mesh:

Year:  2003        PMID: 12695197      PMCID: PMC8148680     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  3 in total

1.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences.

Authors:  R V Mulkern; S T Wong; C Winalski; F A Jolesz
Journal:  Magn Reson Imaging       Date:  1990       Impact factor: 2.546

2.  T1-weighted MR imaging of the brain using a fast inversion recovery pulse sequence.

Authors:  J N Rydberg; C A Hammond; J Huston; C R Jack; R C Grimm; S J Riederer
Journal:  J Magn Reson Imaging       Date:  1996 Mar-Apr       Impact factor: 4.813

3.  MR imaging: clinical use of the inversion recovery sequence.

Authors:  G M Bydder; I R Young
Journal:  J Comput Assist Tomogr       Date:  1985 Jul-Aug       Impact factor: 1.826

  3 in total
  6 in total

1.  A prospective comparison study of fast T1 weighted fluid attenuation inversion recovery and T1 weighted turbo spin echo sequence at 3 T in degenerative disease of the cervical spine.

Authors:  K Ganesan; G M Bydder
Journal:  Br J Radiol       Date:  2014-07-10       Impact factor: 3.039

2.  Consensus recommendations for a standardized brain tumor imaging protocol for clinical trials in brain metastases.

Authors:  Timothy J Kaufmann; Marion Smits; Jerrold Boxerman; Raymond Huang; Daniel P Barboriak; Michael Weller; Caroline Chung; Christina Tsien; Paul D Brown; Lalitha Shankar; Evanthia Galanis; Elizabeth Gerstner; Martin J van den Bent; Terry C Burns; Ian F Parney; Gavin Dunn; Priscilla K Brastianos; Nancy U Lin; Patrick Y Wen; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2020-06-09       Impact factor: 12.300

3.  MR T1-weighted inversion recovery imaging in detecting brain metastases: could it replace T1-weighted spin-echo imaging?

Authors:  Y-F Qian; C-L Yu; C Zhang; Y-Q Yu
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-09       Impact factor: 3.825

4.  Contrast-enhanced synthetic MRI for the detection of brain metastases.

Authors:  Akifumi Hagiwara; Masaaki Hori; Michimasa Suzuki; Christina Andica; Misaki Nakazawa; Kouhei Tsuruta; Nao Takano; Shuji Sato; Nozomi Hamasaki; Mariko Yoshida; Kanako Kunishima Kumamaru; Kuni Ohtomo; Shigeki Aoki
Journal:  Acta Radiol Open       Date:  2016-02-15

5.  Comparison of T1wFLAIR and T1wTSE sequences in imaging the brain of small animals using high-field MRI.

Authors:  Chiara Bergamino; Séamus Hoey; Kenneth Waller; Cliona Skelly
Journal:  Ir Vet J       Date:  2019-07-06       Impact factor: 2.146

6.  Hyperintense Acute Reperfusion Marker on FLAIR in a Patient with Transient Ischemic Attack.

Authors:  Alex Förster; Holger Wenz; Christoph Groden
Journal:  Case Rep Radiol       Date:  2016-04-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.