Literature DB >> 12694733

Quantifying F2-isoprostanes in umbilical cord blood of newborn by gas chromatography-mass spectrometry.

Kai On Chu1, Chi Chiu Wang, Michael Scott Rogers, Chi Pui Pang.   

Abstract

We attempted to improve the extraction procedures to determine the F(2)-isoprostanes in plasma of umbilical cord arterial and venous blood by gas chromatography mass spectrometry. Plasma samples were deproteinized and hydrolyzed; free and esterified F(2)-isoprostanes were extracted by solid-phase extraction columns with citric acid/methanol/cyclohexane and ammonia solution/methanol and then derivatized by PFBBr and BSTFA. Concentrations of total plasma F(2)-isoprostanes eluted at the retention time of an internal standard of 8-iso-prostaglandin F(2alpha)-D(4) were quantified. The absolute recovery was 83+/-1.9% (95% confidence). Intraassay precision and interassay precision were lower than 1.0%. Analytical accuracy was 99.0+/-0.4% (95% confidence). Linearity, r(2), over the concentration range of 10 to 5000 pg/ml of spiked 8-iso-prostaglandin F(2alpha) in plasma was 0.9985. The method detection limit was 21 pg/ml (99% confidence) and the limit of quantitation was approximately 4 pg/ml. Analysis of 200 neonatal cord blood samples revealed few overlapping peaks causing interference in the elution of the F(2)-isoprostanes. With the use of an autosampler and one technician, 48 samples can be completed within 24h with 6h of actual hands-on work. This method could be potentially employed for routine analysis of plasma F(2)-isoprostanes in clinical laboratories.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12694733     DOI: 10.1016/s0003-2697(03)00043-5

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

Review 1.  Biomarkers of exposure to vitamins A, C, and E and their relation to lipid and protein oxidation markers.

Authors:  Lars O Dragsted
Journal:  Eur J Nutr       Date:  2008-05       Impact factor: 5.614

Review 2.  Mass Spectrometry in Advancement of Redox Precision Medicine.

Authors:  Xiaofei Chen; Jingyun Lee; Hanzhi Wu; Allen W Tsang; Cristina M Furdui
Journal:  Adv Exp Med Biol       Date:  2019       Impact factor: 3.650

3.  An efficient sample preparation method for high-throughput analysis of 15(S)-8-iso-PGF2α in plasma and urine by enzyme immunoassay.

Authors:  A Bielecki; G Saravanabhavan; E Blais; R Vincent; P Kumarathasan
Journal:  J Anal Toxicol       Date:  2012-09-18       Impact factor: 3.367

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.