Literature DB >> 12690348

Fracture resistance of endodontically treated teeth restored with composite posts.

Marcela P Newman1, Peter Yaman, Joseph Dennison, Mary Rafter, Edward Billy.   

Abstract

STATEMENT OF PROBLEM: The most recent application of fiber-reinforced composites involves their use as post and core systems to restore endodontically treated teeth. Even though this last application has been advertised and used clinically by many dentists, there is very little information regarding the physical properties of these post systems.
PURPOSE: The purpose of this study was to compare the effect of 3 fiber-reinforced composite post systems on the fracture resistance and mode of failure of endodontically treated teeth.
MATERIAL AND METHODS: Ninety maxillary central incisors were divided into 8 experimental groups and 1 stainless steel (ParaPost) control group of 10 specimens each. Eighty teeth were assigned to 2 main experimental groups called "narrow" and "flared" canals. For the narrow canal group, post spaces were prepared with the corresponding reamer to restore the teeth with FibreKor, Luscent anchors, and Ribbond posts of 1.5 mm, 1.6 mm, and 2.0 mm in diameter, respectively. For the flared canals group thin-walled canals were simulated. Teeth for the flared canals were restored with the same posts but were cemented into tapered 2 mm wide canals created with a tapered diamond bur. Prefabricated posts (FibreKor and Luscent anchors) for narrow and flared canals were cemented with an autopolymerized resin cement and a flowable composite, respectively, whereas customized Ribbond posts were luted with a light-polymerized flowable composite for both canal types. An additional set of 20 Ribbond posts with coronal portions of variable size and shape referred to as "Ribbond nonstandardized" were also prepared and evaluated. Specimens were loaded to failure (kg) with a universal testing machine at a crosshead speed of 0.05 cm/min until failure occurred. Data were analyzed with analysis of variance and Student t tests (P<.05).
RESULTS: Statistical analysis revealed no significant difference between flared and narrow canals in mean load to failure between the post systems except for the Ribbond posts (P<.01). For the narrow canal, the mean load ranged from a low of 4.55 (+/-1.49) kg for the Ribbond standard to a high of 12.9 (+/-1.64) kg for the Luscent anchors. For the flared canal the low mean was 9.04 (+/-1.76) kg for FibreKor and the high was equal for both Luscent anchors and Ribbond standard, 12.87 (+/-2.69) and 12.87 (+/-3.54), respectively. Overall, the ParaPost control group had the highest load value (18.33 +/- 3.27 kg) (P<.05). Ribbond nonstandardized had a mean load to failure of 24.91 (+/-11.53) Kg for the narrow canal group and 31.95 (+/-11.98) kg for the flared canal. Results from these groups were excluded from the statistical analysis because of the uncontrolled core sizes and high standard deviations. No root fractures occurred in any of the experimental groups.
CONCLUSION: Results from the study show that the load to failure of the stainless steel posts were significantly stronger than all the composite posts studied. However, the mode of failure or deflection of the fiber-reinforced composite posts is protective to the remaining tooth structure.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12690348     DOI: 10.1067/mpr.2003.75

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  40 in total

1.  In vitro evaluation of the effect of post system and length on the fracture resistance of endodontically treated human anterior teeth.

Authors:  Sahil Jindal; Ritu Jindal; Sandeep Mahajan; Rohini Dua; Namita Jain; Sunila Sharma
Journal:  Clin Oral Investig       Date:  2012-01-14       Impact factor: 3.573

2.  Can cement film thickness influence bond strength and fracture resistance of fiber reinforced composite posts?

Authors:  Alice Gonçalves Penelas; Valery Martins Piedade; Ana Carolina Oliveira da Silva Borges; Laiza Tatiana Poskus; Eduardo Moreira da Silva; José Guilherme Antunes Guimarães
Journal:  Clin Oral Investig       Date:  2015-08-29       Impact factor: 3.573

3.  Resistance to cyclic loading of teeth restored with posts.

Authors:  A Sahafi; A Peutzfeldt; G Ravnholt; E Asmussen; K Gotfredsen
Journal:  Clin Oral Investig       Date:  2005-03-04       Impact factor: 3.573

4.  [Investigation on the short-term clinical application of two types of glass fiber posts].

Authors:  Hui Song; Jingwen Wang; Xuliang Deng; Yan Wei
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2014-08

5.  The use of endodontically treated and/or fiber post-retained teeth as abutments for fixed partial dentures.

Authors:  Serhan Akman; Melek Akman; Gürcan Eskitaşcıoğlu; Sema Belli
Journal:  Clin Oral Investig       Date:  2011-11-25       Impact factor: 3.573

6.  The effect of the post length and cusp coverage on the cycling and static load of endodontically treated maxillary premolars.

Authors:  Nicola Scotti; Marco Scansetti; Riccardo Rota; Francesco Pera; Damiano Pasqualini; Elio Berutti
Journal:  Clin Oral Investig       Date:  2010-09-10       Impact factor: 3.573

7.  In vitro evaluation of glass fiber post.

Authors:  Jasjit Kaur; Navneet Sharma; Harpal Singh
Journal:  J Clin Exp Dent       Date:  2012-10-01

8.  Does an intracanal composite anchorage replace posts?

Authors:  Gabriel Krastl; Andres Izquierdo; Leonard Büttel; Nicola U Zitzmann; Marc Schmitter; Roland Weiger
Journal:  Clin Oral Investig       Date:  2013-03-16       Impact factor: 3.573

9.  An in vitro evaluation of fracture strength of endodontically treated teeth with simulated flared root canals restored with different post and core systems.

Authors:  Jayshree Hegde; Kusum Bashetty
Journal:  J Conserv Dent       Date:  2012-07

10.  Comparative evaluation of the reinforcing effect of different post systems in the restoration of endodontically treated human anterior teeth at two different lengths of post space preparation- an in vitro study.

Authors:  Sahil Jindal; Ritu Jindal; Kanika Gupta; Sandeep Mahajan; Sunidhi Garg
Journal:  J Dent (Tehran)       Date:  2013-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.