Literature DB >> 12683849

Effect of fiber optic probe geometry on depth-resolved fluorescence measurements from epithelial tissues: a Monte Carlo simulation.

Changfang Zhu1, Quan Liu, Nirmala Ramanujam.   

Abstract

Developing fiber optic probe geometries to selectively measure fluorescence spectra from different sublayers within human epithelial tissues will potentially improve the endogenous fluorescence contrast between neoplastic and nonneoplastic tissues. In this study, two basic fiber optic probe geometries, which are called the variable aperture (VA) and multidistance (MD) approaches, are compared for depth-resolved fluorescence measurements from human cervical epithelial tissues. The VA probe has completely overlapping illumination and collection areas with variable diameters, while the MD probe employs separate illumination and collection fibers with a fixed separation between them. Monte Carlo simulation results show that the total fluorescence detected is significantly higher for the VA probe geometry, while the probing depth is significantly greater for the MD probe geometry. An important observation is that the VA probe is more sensitive to the epithelial layer, while the MD probe is more sensitive to the stromal layer. The effect of other factors, including numerical aperture (NA) and tissue optical properties on the fluorescence measurements with VA and MD probe geometries, are also evaluated. The total fluorescence detected with both probe geometries significantly increases when the fiber NA is changed from 0.22 to 0.37. The sensitivity to different sublayers is found to be strongly dependent on the tissue optical properties. The simulation results are used to design a simple fiber optic probe that combines both the VA and MD geometries to enable fluorescence measurements from the different sublayers within human epithelial tissues.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12683849     DOI: 10.1117/1.1559058

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  20 in total

1.  Limitations of the commonly used simplified laterally uniform optical fiber probe-tissue interface in Monte Carlo simulations of diffuse reflectance.

Authors:  Peter Naglič; Franjo Pernuš; Boštjan Likar; Miran Bürmen
Journal:  Biomed Opt Express       Date:  2015-09-11       Impact factor: 3.732

2.  Ball lens coupled fiber-optic probe for depth-resolved spectroscopy of epithelial tissue.

Authors:  Richard A Schwarz; Dizem Arifler; Sung K Chang; Ina Pavlova; Insiya A Hussain; Vivian Mack; Bob Knight; Rebecca Richards-Kortum; Ann M Gillenwater
Journal:  Opt Lett       Date:  2005-05-15       Impact factor: 3.776

3.  Influence of illumination-collection geometry on fluorescence spectroscopy in multilayer tissue.

Authors:  T J Pfefer; L S Matchette; R Drezek
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

4.  Reflectance spectroscopy for diagnosis of epithelial precancer: model-based analysis of fiber-optic probe designs to resolve spectral information from epithelium and stroma.

Authors:  Dizem Arifler; Richard A Schwarz; Sung K Chang; Rebecca Richards-Kortum
Journal:  Appl Opt       Date:  2005-07-10       Impact factor: 1.980

Review 5.  A review of attenuation correction techniques for tissue fluorescence.

Authors:  Robert S Bradley; Maureen S Thorniley
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

6.  Portable, Fiber-Based, Diffuse Reflection Spectroscopy (DRS) Systems for Estimating Tissue Optical Properties.

Authors:  Karthik Vishwanath; Kevin Chang; Daniel Klein; Yu Feng Deng; Vivide Chang; Janelle E Phelps; Nimmi Ramanujam
Journal:  Appl Spectrosc       Date:  2011-02-01       Impact factor: 2.388

7.  Monte Carlo model to describe depth selective fluorescence spectra of epithelial tissue: applications for diagnosis of oral precancer.

Authors:  Ina Pavlova; Crystal Redden Weber; Richard A Schwarz; Michelle Williams; Adel El-Naggar; Ann Gillenwater; Rebecca Richards-Kortum
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

8.  Depth-enhanced fluorescence imaging using masked detection of structured illumination.

Authors:  Joseph Angelo; Vivek Venugopal; Frederic Fantoni; Vincent Poher; Irving J Bigio; Lionel Herve; Jean-Marc Dinten; Sylvain Gioux
Journal:  J Biomed Opt       Date:  2014       Impact factor: 3.170

9.  Sub-millimeter resolution 3D optical imaging of living tissue using laminar optical tomography.

Authors:  Elizabeth M C Hillman; Sean A Burgess
Journal:  Laser Photon Rev       Date:  2009-02-01       Impact factor: 13.138

Review 10.  Advances in quantitative UV-visible spectroscopy for clinical and pre-clinical application in cancer.

Authors:  J Quincy Brown; Karthik Vishwanath; Gregory M Palmer; Nirmala Ramanujam
Journal:  Curr Opin Biotechnol       Date:  2009-03-04       Impact factor: 9.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.