Literature DB >> 12676971

Analysis of cardiopulmonary transit times at contrast material-enhanced MR imaging in patients with heart disease.

Christopher J Francois1, Stephanie M Shors, Robert O Bonow, J Paul Finn.   

Abstract

PURPOSE: To build a database of arm-to-aorta circulation times for contrast enhancement and to determine if measured transit times can help in discrimination between patients with and patients without heart disease.
MATERIALS AND METHODS: Findings at test-bolus examinations performed before acquisition of contrast material-enhanced magnetic resonance (MR) angiographic images of the head and neck were retrospectively reviewed. The times from test-bolus injection to first and peak enhancement in regions of interest were recorded in 77 patients with coronary artery disease, left ventricular hypertrophy, and/or impaired left ventricular function and 33 control subjects. Transit times in patients and control subjects were compared with Student t test. Linear regression was performed to measure the correlation coefficient.
RESULTS: Transit times in patients with heart disease, including those with a normal ejection fraction, were significantly prolonged compared with those in control subjects (P <.05). Mean time to peak enhancement in the carotid artery bifurcation was 16.6 seconds +/- 1.9 (SD) and 20.8 seconds +/- 3.9 in control subjects and patients, respectively. Threshold value of 18 seconds for time to peak signal intensity in the carotid artery bifurcation provided highest combination of sensitivity and specificity. All (11 of 11) patients with an ejection fraction less than 40% and only three (9%) of 33 control subjects had circulation times greater than this threshold. No significant correlation was found between transit times and age, sex, weight, and height.
CONCLUSION: Transit times measured with MR imaging may help in discrimination between patients with and patients without heart disease, independently of other cardiac functional parameters. Copyright RSNA, 2003

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12676971     DOI: 10.1148/radiol.2272020366

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

2.  Time-resolved magnetic resonance angiography: evaluation of intrapulmonary circulation parameters in pulmonary arterial hypertension.

Authors:  Hyun J Jeong; Parmede Vakil; John J Sheehan; Sanjiv J Shah; Michael Cuttica; James C Carr; Timothy J Carroll; Amir Davarpanah
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

Review 3.  Evaluation of intracardiac shunts with cardiac magnetic resonance.

Authors:  Patrick M Colletti
Journal:  Curr Cardiol Rep       Date:  2005-01       Impact factor: 2.931

4.  Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

Authors:  C Fink; M Puderbach; S Ley; J Zaporozhan; C Plathow; H-U Kauczor
Journal:  Eur Radiol       Date:  2005-06-30       Impact factor: 5.315

5.  A simple method to estimate cardiac function during routine multi-row detector CT exams.

Authors:  Piet K Vanhoenacker; Lieven R Van Hoe
Journal:  Eur Radiol       Date:  2007-02-03       Impact factor: 5.315

6.  Pulmonary arterial hypertension: MR imaging-derived first-pass bolus kinetic parameters are biomarkers for pulmonary hemodynamics, cardiac function, and ventricular remodeling.

Authors:  Jan Skrok; Monda L Shehata; Stephen Mathai; Reda E Girgis; Ari Zaiman; James O Mudd; Danielle Boyce; Noah Lechtzin; João A C Lima; David A Bluemke; Paul M Hassoun; Jens Vogel-Claussen
Journal:  Radiology       Date:  2012-04-16       Impact factor: 11.105

7.  Contrast-kinetics-resolved whole-heart coronary MRA using 3DPR.

Authors:  Peng Lai; Feng Huang; Yu Li; Sonia Nielles-Vallespin; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

Review 8.  Quantitative magnetic resonance imaging of pulmonary hypertension: a practical approach to the current state of the art.

Authors:  Andrew J Swift; Jim M Wild; Scott K Nagle; Alejandro Roldán-Alzate; Christopher J François; Sean Fain; Kevin Johnson; Dave Capener; Edwin J R van Beek; David G Kiely; Kang Wang; Mark L Schiebler
Journal:  J Thorac Imaging       Date:  2014-03       Impact factor: 3.000

9.  Dynamic contrast-enhanced magnetic resonance imaging in patients with pulmonary arterial hypertension.

Authors:  Andrew J Swift; Adam Telfer; Smitha Rajaram; Robin Condliffe; Helen Marshall; Dave Capener; Judith Hurdman; Charlie Elliot; David G Kiely; Jim M Wild
Journal:  Pulm Circ       Date:  2014-03       Impact factor: 3.017

10.  Right ventricular plasticity and functional imaging.

Authors:  Evan L Brittain; Anna R Hemnes; Mary Keebler; Mark Lawson; Benjamin F Byrd; Tom Disalvo
Journal:  Pulm Circ       Date:  2012-07       Impact factor: 3.017