Literature DB >> 12676969

Hepatic arteries in potential donors for living related liver transplantation: evaluation with multi-detector row CT angiography.

Seung Soo Lee1, Tae Kyoung Kim, Jae Ho Byun, Hyun Kwon Ha, Pyo Nyun Kim, Ah Young Kim, Sung Gyu Lee, Moon-Gyu Lee.   

Abstract

PURPOSE: To assess the accuracy of multi-detector row computed tomographic (CT) angiography in the evaluation of hepatic arterial anatomy in living related liver transplantation (LRLT) donors.
MATERIALS AND METHODS: During a 10-month period, 62 potential LRLT donors were evaluated with CT and conventional angiography. Multi-detector row CT was performed after intravenous injection of 150 mL of contrast material at 3 mL/sec. CT angiograms of the hepatic arteries were generated by a radiologist who used volume rendering and maximum intensity projection techniques without knowledge of results of conventional angiography. Two reviewers reviewed CT and conventional angiograms retrospectively in consensus. The results of the two examinations were then compared.
RESULTS: CT examinations were technically adequate in 56 (90%) donors. Respiratory motion artifact compromised detailed hepatic artery analysis in six donors (10%). Second-order branches of right hepatic arteries were visualized in 58 donors (94%), and second-order branches of left hepatic arteries were visualized in 51 (82%). A total of 27 hepatic arterial anatomic variations were detected in 22 donors at conventional angiography. CT angiography accurately depicted 25 (93%) anatomic variations in 20 donors (91%). CT angiography did not depict an accessory right hepatic artery in two donors. The number and origins of dominant arteries supplying segment IV were accurately identified at CT angiography in 51 donors (82%). Hepatic arterial anatomy depicted at CT angiography was identical to that at conventional angiography in 50 donors (81%).
CONCLUSION: Multi-detector row CT angiography is useful but limited in its ability to depict the dominant artery supplying segment IV and small accessory hepatic arteries. Copyright RSNA, 2003

Mesh:

Year:  2003        PMID: 12676969     DOI: 10.1148/radiol.2272012033

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  11 in total

1.  Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

Authors:  Takashi Shirasaka; Yoshinori Funama; Mutsukazu Hayashi; Shinichi Awamoto; Masatoshi Kondo; Yasuhiko Nakamura; Masamitsu Hatakenaka; Hiroshi Honda
Journal:  Radiol Phys Technol       Date:  2011-10-15

2.  Computed tomography reflected endocrine function of the pancreas.

Authors:  Naoaki Sakata; Shinichi Egawa; Toshiki Rikiyama; Gumpei Yoshimatsu; Kunihiro Masuda; Hideo Ohtsuka; Shigeru Ottomo; Kei Nakagawa; Hiroki Hayashi; Takanori Morikawa; Tohru Onogawa; Kuniharu Yamamoto; Hiroshi Yoshida; Masanori Akada; Fuyuhiko Motoi; Takeshi Naitoh; Yu Katayose; Michiaki Unno
Journal:  J Gastrointest Surg       Date:  2010-12-23       Impact factor: 3.452

3.  Normal vascular and biliary hepatic anatomy: 3D demonstration by multidetector CT.

Authors:  P Donato; P Coelho; H Rodrigues; E Vigia; J Fernandes; F Caseiro-Alves; A Bernardes
Journal:  Surg Radiol Anat       Date:  2007-07-19       Impact factor: 1.246

4.  Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: improvement of image quality.

Authors:  Izuru Matsuda; Shohei Hanaoka; Masaaki Akahane; Jiro Sato; Shuuhei Komatsu; Shinichi Inoh; Shigeru Kiryu; Naoki Yoshioka; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2010-11-27       Impact factor: 2.374

5.  Anatomic variations of arterial liver vascularization: an analysis by using MDCTA.

Authors:  Luca Saba; Giorgio Mallarini
Journal:  Surg Radiol Anat       Date:  2011-01-20       Impact factor: 1.246

6.  MDCT angiography of pediatric vascular diseases of the abdomen, pelvis, and extremities.

Authors:  Frandics P Chan; Geoffrey D Rubin
Journal:  Pediatr Radiol       Date:  2004-11-25

7.  Imaging diagnosis of aberrant proper hepatic and gastroduodenal arteries prior to pancreaticoduodenectomy: A case report.

Authors:  Yosuke Namba; Koichi Oishi; Sho Okimoto; Toshiyuki Moriuchi; Tomoaki Bekki; Shoichiro Mukai; Yasufumi Saito; Seiji Fujisaki; Mamoru Takahashi; Toshikatsu Fukuda; Hideki Ohdan
Journal:  Radiol Case Rep       Date:  2021-04-30

8.  Multidetector computed tomographic angiography evaluation of micropig major systemic vessels for xenotransplantation.

Authors:  Jung Min Ryu; Woong Yoon; Jae Hong Park; Seung Pil Yun; Min Woo Jang; Ho Jae Han
Journal:  J Vet Sci       Date:  2011-09       Impact factor: 1.672

9.  Three-dimensional imaging for hepatobiliary and pancreatic diseases: Emphasis on clinical utility.

Authors:  Soo Jin Kim; Byung Ihn Choi; Se Hyung Kim; Jae Young Lee
Journal:  Indian J Radiol Imaging       Date:  2009-02

10.  Imaging evaluation of the liver using multi-detector row computed tomography in micropigs as potential living liver donors.

Authors:  Jung Min Ryu; Dong Hyun Kim; Min Young Lee; Sang Hun Lee; Jae Hong Park; Seung Pil Yun; Min Woo Jang; Seong Hwan Kim; Gyu Jin Rho; Ho Jae Han
Journal:  J Vet Sci       Date:  2009-06       Impact factor: 1.672

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.