Literature DB >> 12667314

Dosimetric impact of correcting count losses due to deadtime in clinical radioimmunotherapy trials involving iodine-131 scintigraphy.

Ludovic Ferrer1, Grégory Delpon, Albert Lisbona, Manuel Bardiès.   

Abstract

This study describes the use of a new method for correcting count losses due to deadtime in the context of quantitative imaging of patients undergoing scintigraphy after a 4 GBq therapeutic injection of iodine-131. This method, based on measuring the count rate observed throughout the spectrum detected (50-750 keV), had been validated in a previous study and was applied here to 10 patients. Imaging was performed 3, 6, 8 and 10 days after injection. Whole-body images were acquired in six steps in energy-indexed list mode. Before reconstruction of the whole-body image, each step was processed to obtain an appropriate correction. Three days after injection, corrective factors ranged between 1.01 (feet) and 1.20 (liver), and the increase in whole-body activity was estimated at around 10%. The difference between whole-body activities calculated from images corrected for deadtime and those estimated by urine collection was around 1% when urine collection was complete. Correction for count losses led to an 11% increase in whole-body cumulated activity. These results indicate that it is possible to integrate this correction into dosimetric studies in order to allow count rate variations to be taken into account as a function of the regions imaged. Although the complexity of acquisitions in energy-indexed list mode limits the systematic use of this method, it can be simplified if corrections are made only for those steps in which the correction factor exceeds a threshold value. However, this implies a selection of the regions to be corrected. Another possibility consists in acquiring spectrometric images in several windows, which also allows correction for count losses.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12667314     DOI: 10.1089/108497803321269395

Source DB:  PubMed          Journal:  Cancer Biother Radiopharm        ISSN: 1084-9785            Impact factor:   3.099


  3 in total

1.  Spatial resolution and image qualities of Zr-89 on Siemens Biograph TruePoint PET/CT.

Authors:  Young Sub Lee; Jin Su Kim; Jung Young Kim; Byung Il Kim; Sang Moo Lim; Hee-Joung Kim
Journal:  Cancer Biother Radiopharm       Date:  2014-12-30       Impact factor: 3.099

2.  Characterization of the count rate performance of modern gamma cameras.

Authors:  M Silosky; V Johnson; C Beasley; S Cheenu Kappadath
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

3.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.