Literature DB >> 12666712

Immediate functional and non-functional loading of dental implants: a 2- to 60-month follow-up study of 646 titanium implants.

Marco Degidi1, Adriano Piattelli.   

Abstract

BACKGROUND: The aim of this study was the evaluation, from a clinical point of view, of implants subjected to immediate functional loading (IFL) and to immediate non-functional loading (INFL) in various anatomical configurations.
METHODS: The study included 152 patients who had given their informed consent. A total of 646 implants were inserted. The implants were placed in 39 totally edentulous mandibles, 14 edentulous maxillae, 23 edentulous posterior mandibles, 16 edentulous anterior mandibles, 16 edentulous anterior maxillae, and 15 edentulous posterior maxillae. Fifty-eight implants were used to replace single missing teeth. In 65 cases, IFL was carried out for 422 implants. INFL was carried out in 116 cases, (224 implants).
RESULTS: In the IFL group 6 of 422 implants failed (1.4%); in the INFL group 2 of 224 implants failed (0.9%). All the other implants appeared, from clinical and radiographic observations, to have successfully osseointegrated and have been functioning satisfactorily since insertion. All failures were observed in the first few months after implant loading.
CONCLUSION: Immediate functional and non-functional loading seems to be a technique that gives satisfactory results in selected cases.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12666712     DOI: 10.1902/jop.2003.74.2.225

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  10 in total

1.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

2.  Spectrum of indications for palatal implants in treatment concepts involving immediate and conventional loading.

Authors:  Britta A Jung; Winfried Harzer; Tomasz Gedrange; Martin Kunkel; Maximilian Moergel; Peter Diedrich; Gabriele Lüdicke; Heiner Wehrbein
Journal:  J Orofac Orthop       Date:  2010-07-30       Impact factor: 1.938

3.  Immediate versus conventional loading of palatal implants in humans: a first report of a multicenter RCT.

Authors:  Britta A Jung; Winfried Harzer; Heinrich Wehrbein; Tomasz Gedrange; Werner Hopfenmüller; Gabriele Lüdicke; Maximilian Moergel; Peter Diedrich; Martin Kunkel
Journal:  Clin Oral Investig       Date:  2010-04-10       Impact factor: 3.573

4.  Effect of Magnetic Field on Bone Healing around Endosseous Implants - An In-vivo Study.

Authors:  Mahalakshmi Gujjalapudi; Chandrasekar Anam; Praveen Mamidi; Radha Chiluka; A Gautam Kumar; Ragini Bibinagar
Journal:  J Clin Diagn Res       Date:  2016-10-01

5.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14

6.  Short implants: A systematic review.

Authors:  I Karthikeyan; Shrikar R Desai; Rika Singh
Journal:  J Indian Soc Periodontol       Date:  2012-07

7.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

Review 8.  A Systematic Review of Survival Rates of Osseointegrated Implants in Fully and Partially Edentulous Patients Following Immediate Loading.

Authors:  Massimo Del Fabbro; Tiziano Testori; Vladan Kekovic; Funda Goker; Margherita Tumedei; Hom-Lay Wang
Journal:  J Clin Med       Date:  2019-12-04       Impact factor: 4.241

9.  Marginal Bone Level Evaluation of Fixed Partial Dental Prostheses Using Preformed Stock versus CAD/CAM Customized Abutments.

Authors:  Hui-Ting Lin; Jerry Chin-Yi Lin; Eisner Salamanca; Odontuya Dorj; Yu-Hwa Pan; Yi-Fan Wu; Yung-Szu Hsu; Chih-Yuan Fang; Wei-Jen Chang
Journal:  J Pers Med       Date:  2022-06-27

10.  Comparative evaluation of two types of immediately loaded implants using biomechanical and histomorphometric tests: an animal case study.

Authors:  Mansour Rismanchian; Bijan Movahedian; Navid Khalighinejad; Hamid Badrian; Sayed Mohammad Razavi; Afsaneh Nekouie
Journal:  ISRN Dent       Date:  2012-07-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.