Literature DB >> 12664993

Performance evaluation of two multiplexes used in fluorescent short tandem repeat DNA analysis.

Edward L Buse1, Jeanne C Putinier, Mary M Hong, Aimee E Yap, John M Hartmann.   

Abstract

The performance of two commercial multiplex kits that together amplify the 13 core short tandem repeat (STR) loci currently in use by forensic laboratories and the U.S. national Combined DNA Indexing System (CODIS) were evaluated. The typing systems examined were AmpFlSTR Profiler Plus and AmpFlSTR COfiler (PE Applied Biosystems, Foster City, CA). Electrophoretic separation and detection of the fluorescent PCR products was achieved by capillary electrophoresis (CE) using an ABI Prism 310 Genetic Analyzer. The studies addressed the on-site validation of the instrument, the software, and each typing system. These studies included instrument sensitivity, resolution, precision, binning, peak height ratios, mixtures, stutter, and the amplification of non-probative and simulated forensic samples. Other additional developmental-type work is also reported herein, such as species specificity testing and amplification of environmentally insulted samples. Amplification conditions were found to be robust and the primer sets shown to be specific to human DNA. Stutter and peak height ratios fell within limits published by the manufacturer and other laboratories. The data demonstrate that the CE instrument can consistently resolve fragments differing in length by one base and that the +/-0.5 base bin used by the Genotyper software is acceptable for making accurate allele calls. Correct typing results were obtained from non-probative and simulated case samples, as well as samples exposed to outdoor environmental conditions. The results support the conclusion that DNA extracted from biological samples routinely encountered in the forensic laboratory can be reliably analyzed with AmpFlSTR Profiler Plus and COfiler using CE.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12664993

Source DB:  PubMed          Journal:  J Forensic Sci        ISSN: 0022-1198            Impact factor:   1.832


  4 in total

1.  Variations in short tandem repeats deduced on the basis of the number of repeats and the relationship of these variations with longevity.

Authors:  Liu Hui; Yu Weijian; Deng Xuelian; Liu Qigui
Journal:  Age (Dordr)       Date:  2010-06-29

2.  Screening of cerebral infarction-related genetic markers using a Cox regression analysis between onset age and heterozygosity at randomly selected short tandem repeat loci.

Authors:  Liu Hui; Tian Jun; Ye Jing; Weijian Yu
Journal:  J Thromb Thrombolysis       Date:  2012-05       Impact factor: 2.300

3.  Canine haematopoietic chimerism analyses by semiquantitative fluorescence detection of variable number of tandem repeat polymorphism.

Authors:  I Hilgendorf; V Weirich; L Zeng; E Koppitz; R Wegener; C Junghanss
Journal:  Vet Res Commun       Date:  2005-02       Impact factor: 2.459

4.  Effects of electron-beam irradiation on buccal-cell DNA.

Authors:  Philip E Castle; Montserrat Garcia-Closas; Tracie Franklin; Stephen Chanock; Vinita Puri; Robert Welch; Nathaniel Rothman; Jim Vaught
Journal:  Am J Hum Genet       Date:  2003-08-13       Impact factor: 11.025

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.