Literature DB >> 12664818

Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device.

Peter Koenig1, Qi-Ling Cao, Mary Heitschmidt, David J Waight, Ziyad M Hijazi.   

Abstract

Transesophageal echocardiography (TEE) has been successfully used for guiding transcatheter device closure of secundum atrial septal defect (ASD) and patent foramen ovale (PFO). However, the use of TEE for device closure requires general anesthesia. Experience with intracardiac echocardiographic (ICE) guidance to close ASD and PFO is limited. One hundred eleven patients (76 female/35 male) with secundum ASD (82 patients) and PFO (29 patients) associated with a stroke underwent an attempt of transcatheter closure of their defects under ICE guidance using the new AcuNav catheter. The median age of patients was 40 years (range 2.5-80.7) and the median weight was 66 kg (range 12.7-128 kg). The median two-dimensional size of secundum defects as measured by ICE was 17 mm (range 3-32 mm). The median balloon stretched diameter of the ASDs was 22 mm (range 4-36 mm). Five patients had more than one defect that required placement of two devices to close the defects. The median Qp/QS ratio for patients with secundum ASD was 2.1 (range 1-18). ICE provided adequate views of the defects and surrounding structures and the various stages of device deployment. All patients had successful device placement, including the patients who received simultaneous two devices with immediate complete closure of the defects in 100 patients, whereas four and seven patients had trivial and small residual shunt, respectively. The median fluoroscopy time was 10.2 minutes (range 3.7-38.4 minutes) and the median total procedure time was 60 minutes (range 28-180 minutes). There were no complications related to the use of the AcuNav catheter. We conclude that ICE provided unique images of the atrial communications and facilitated device closure of secundum ASD and PFO in children and adults. We believe ICE should replace TEE as a guiding imaging tool for ASD and PFO device closure, thus eliminating the need for general anesthesia.

Entities:  

Mesh:

Year:  2003        PMID: 12664818     DOI: 10.1046/j.1540-8183.2003.08003.x

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  12 in total

Review 1.  Echocardiographic guidance of transcatheter closure of atrial septal defects: is intracardiac echocardiography better than transesophageal echocardiography?

Authors:  P Koenig; Q L Cao
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

2.  Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

Authors:  Stephen J Hsu; Brian J Fahey; Douglas M Dumont; Patrick D Wolf; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

Review 3.  Contemporary echocardiographic guiding tools for device closure of interatrial communications.

Authors:  Thomas Bartel; Silvana Müller
Journal:  Cardiovasc Diagn Ther       Date:  2013-03

4.  The use of intracardiac echocardiography during percutaneous pulmonary valve replacement.

Authors:  Sawsan M Awad; Syed Asif Masood; Ismael Gonzalez; Qi-Ling Cao; Ra-id Abdulla; Mary G Heitschmidt; Ziyad M Hijazi
Journal:  Pediatr Cardiol       Date:  2014-07-29       Impact factor: 1.655

Review 5.  Intracardiac echocardiography in congenital heart disease.

Authors:  Piers C A Barker
Journal:  J Cardiovasc Transl Res       Date:  2009-01-23       Impact factor: 4.132

6.  Safe and efectivef guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Yu Wang; Tao Guo; Guizheng Liang; Ling Zhao; Jiahua Pan; Shumin Li; Baotong Hua; Lijin Pu
Journal:  Int J Clin Exp Med       Date:  2015-05-15

7.  Safe and effective guidance by intracardiac echocardiography for transcatheter closure in atrial septal defects.

Authors:  Jing Zhao; Li Li; Ling Peng
Journal:  Int J Clin Exp Med       Date:  2015-06-15

Review 8.  Transcatheter closure of atrial septal defect: principles and available devices.

Authors:  Se Yong Jung; Jae Young Choi
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

9.  Transcatheter Atrial Septal Defect Closure under Transthorasic Echocardiography in Children.

Authors:  Keyhan Sayadpour Zanjani; Aliakbar Zeinaloo; Elaheh Malekan-Rad; Abdolrazagh Kiani; Mohammad-Mehdi Bagheri
Journal:  Iran J Pediatr       Date:  2011-12       Impact factor: 0.364

10.  Transcatheter closure of secundum atrial septal defect in patients over 60 years old.

Authors:  Saet Byul Woo; So-Ick Jang; Seong-Ho Kim; Soo-Jin Kim; Sang-Yun Lee; Jae-Sook Baek; Woo-Sup Shim
Journal:  Korean Circ J       Date:  2013-02-28       Impact factor: 3.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.