Literature DB >> 25070389

The use of intracardiac echocardiography during percutaneous pulmonary valve replacement.

Sawsan M Awad1, Syed Asif Masood, Ismael Gonzalez, Qi-Ling Cao, Ra-id Abdulla, Mary G Heitschmidt, Ziyad M Hijazi.   

Abstract

High-quality live imaging assessment of cardiac valves and cardiac anatomy is crucial for the success of catheter-based procedures. We present our experience using Intracardiac echocardiography (ICE) during transcatheter Percutaneous Pulmonary Valve replacement (tPVR).This is a retrospective study that included 35 patients who underwent tPVR between April 2008 and June 2012. Thirty-one of these patients had the procedure performed under continuous ICE guidance. Pre-procedure transthoracic echocardiography (TTE) was obtained in all patients. ICE was performed at baseline, during the procedure, and at the conclusion of the procedure. Comparisons between the pre-procedure TTE and baseline ICE data and between post-procedure ICE data and the following day TTE were performed. Total of 35 patients had tPVR during the above-mentioned time period. Twenty-one patients received the Edwards Sapien valve and 14 patients had the Melody valve. Thirty-one patients had the procedure performed under continuous ICE guidance. The mean Pre-TTE peak gradient (PG) and Pre-ICE-PG were 45.5 ± 20 vs 33 ± 13 mmHg (p < 0.001) and the mean Pre-TTE mean gradient (MG) and Pre-ICE-MG were 27.7 ± 13 vs 21 ± 18 mmHg (p < 0.001). The mean Post-TTE- PG and Post-ICE-PG were 24.3 ± 11 vs 15.3 ± 7 mmHg (p < 0.001) and the mean of the Post-TTE-MG and Post-ICE-MG were 14.2 ± 7 vs 8.4 ± 4 mmHg (p < 0.001). There was a good correlation between peak ICE and TTE gradient at baseline and after valve placement. For the degree of pulmonary regurgitation, there was no significant difference between TTE and ICE. ICE is an important modality to guide tPVR in patients with dysfunctional homograft valve between the right ventricle and pulmonary artery and should be used to assess valve function before, during and immediately after the procedure.

Entities:  

Mesh:

Year:  2014        PMID: 25070389     DOI: 10.1007/s00246-014-0967-6

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  30 in total

Review 1.  Intracardiac echocardiography: computerized detection of left ventricular borders.

Authors:  M Sonka; W Liang; P Kanani; J Allan; S DeJong; R Kerber; C McKay
Journal:  Int J Card Imaging       Date:  1998-12

Review 2.  Use of intracardiac echocardiography to guide catheter closure of atrial communications.

Authors:  Peter R Koenig; Ra-id Abdulla; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Echocardiography       Date:  2003-11       Impact factor: 1.724

Review 3.  The use of intracardiac echocardiography and other intracardiac imaging tools to guide noncoronary cardiac interventions.

Authors:  Susan S Kim; Ziyad M Hijazi; Roberto M Lang; Bradley P Knight
Journal:  J Am Coll Cardiol       Date:  2009-06-09       Impact factor: 24.094

4.  An ultrasonic intracardiac scanner.

Authors:  N Bom; C T Lancée; F C Van Egmond
Journal:  Ultrasonics       Date:  1972-03       Impact factor: 2.890

5.  Determination of aortic valve area in valvular aortic stenosis by direct measurement using intracardiac echocardiography: a comparison with the Gorlin and continuity equations.

Authors:  G P Foster; N J Weissman; M H Picard; P J Fitzpatrick; S J Shubrooks; S W Zarich
Journal:  J Am Coll Cardiol       Date:  1996-02       Impact factor: 24.094

6.  Intracardiac ultrasound measurement of volumes and ejection fraction in normal, infarcted, and aneurysmal left ventricles using a 10-MHz ultrasound catheter.

Authors:  C Chen; J L Guerrero; J A Vazquez de Prada; L R Padial; E Schwammenthal; M H Chen; L Jiang; T Svizzero; H Simon; J D Thomas
Journal:  Circulation       Date:  1994-09       Impact factor: 29.690

7.  The Medtronic Melody® transcatheter pulmonary valve implanted at 24-mm diameter--it works.

Authors:  Sharon L Cheatham; Ralf J Holzer; Joanne L Chisolm; John P Cheatham
Journal:  Catheter Cardiovasc Interv       Date:  2013-08-12       Impact factor: 2.692

8.  Intracardiac echocardiography in humans using a small-sized (6F), low frequency (12.5 MHz) ultrasound catheter. Methods, imaging planes and clinical experience.

Authors:  S L Schwartz; L D Gillam; A R Weintraub; B W Sanzobrino; J A Hirst; T L Hsu; J P Fisher; G Marx; D Fulton; R G McKay
Journal:  J Am Coll Cardiol       Date:  1993-01       Impact factor: 24.094

9.  Intracardiac ultrasound imaging during transseptal catheterization.

Authors:  J F Mitchel; L D Gillam; B W Sanzobrino; J A Hirst; R G McKay
Journal:  Chest       Date:  1995-07       Impact factor: 9.410

10.  Intracardiac echocardiography-guided biopsy of intracardiac masses.

Authors:  D S Segar; P D Bourdillon; G Elsner; K Kesler; H Feigenbaum
Journal:  J Am Soc Echocardiogr       Date:  1995 Nov-Dec       Impact factor: 5.251

View more
  4 in total

1.  Intra-cardiac echocardiography-guided stent implantation into stenosed superior vena cava in a patient with a history of contrast anaphylaxis.

Authors:  Hironaga Yoshimoto; Kenji Suda; Shintaro Kishimoto; Yoshiyuki Kudo
Journal:  Heart Vessels       Date:  2015-01-21       Impact factor: 2.037

Review 2.  Echocardiographic guidance of interventions in adults with congenital heart defects.

Authors:  Weiyi Tan; Jamil Aboulhosn
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

Review 3.  Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

Authors:  Craig Basman; Yuvrajsinh J Parmar; Itzhak Kronzon
Journal:  Curr Cardiol Rep       Date:  2017-09-06       Impact factor: 2.931

4.  The Utility of Intracardiac Echocardiography Following Melody™ Transcatheter Pulmonary Valve Implantation.

Authors:  Wendy Whiteside; Sara K Pasquali; Sunkyung Yu; Martin L Bocks; Jeffrey D Zampi; Aimee K Armstrong
Journal:  Pediatr Cardiol       Date:  2015-07-14       Impact factor: 1.655

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.