Literature DB >> 12663970

Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair.

Björn Sonesson1, Nuno Dias, Martin Malina, PerAke Olofsson, Dennis Griffin, Bengt Lindblad, Krassi Ivancev.   

Abstract

PURPOSE: This study was performed to determine intra-aneurysm sac pressure of abdominal aortic aneurysm after endovascular aneurysm repair in patients considered successfully treated with aneurysm shrinkage and absence of endovascular leakage.
METHODS: In 10 patients with median aneurysm shrinkage of 12 mm (range, 7 to 22 mm) and median follow-up of 19 months (range, 14-43 months), a percutaneous translumbar intra-aneurysm pressure measurement was made with a 0.014-inch guide wire-mounted pressure sensor and compared with intra-aortic pressure.
RESULTS: Median intra-aneurysm systolic/diastolic/mean pressure was 19/18/19 (range, 17-35/13-33/17-31) compared with median intra-aortic pressure of 135/75/99 (range, 126-199/60-95/84-129). Mean intra-aneurysm pressure was 20% of mean intra-aortic pressure (range, 13%-33%). Pulsatility was negligible.
CONCLUSION: Successful endovascular aneurysm repair of abdominal aortic aneurysm results in considerable pressure reduction in the aneurysm sac. The ability to monitor intra-aneurysm pressure provides hemodynamic information within the sac, which can be used in conjunction with imaging to determine whether a secondary intervention is warranted.

Entities:  

Mesh:

Year:  2003        PMID: 12663970     DOI: 10.1067/mva.2003.138

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  13 in total

1.  Infrarenal abdominal aortic aneurysm complicated by persistent endotension after endovascular repair: report of a case.

Authors:  Atsushi Imamura; Yasushi Koike; Ryuji Iwaki; Takamichi Saito; Takashi Ozaki; Hironori Tanaka; Hitoshi Yamada; Yasuo Kamiyama
Journal:  Surg Today       Date:  2005       Impact factor: 2.549

2.  Significance of initial aortic aneurysm pressure sensor readings varies with aortic endograft design.

Authors:  Gautam Shrikhande; Sikandar Khan; Hafiz Hussain; Alicia Menezes; James McKinsey; Harry Bush
Journal:  World J Surg       Date:  2010-12       Impact factor: 3.352

3.  Aortic aneurysm sac pressure measurements after endovascular repair using an implantable remote sensor: initial experience and short-term follow-up.

Authors:  Hanno Hoppe; Jocelyn A Segall; Timothy K Liem; Gregory J Landry; John A Kaufman
Journal:  Eur Radiol       Date:  2007-12-20       Impact factor: 5.315

4.  Endoleak following endovascular abdominal aortic aneurysm repair: implications for duration of screening.

Authors:  Matthew A Corriere; Irene D Feurer; Stacey Y Becker; Jeffery B Dattilo; Marc A Passman; Raul J Guzman; Thomas C Naslund
Journal:  Ann Surg       Date:  2004-06       Impact factor: 12.969

5.  Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures.

Authors:  Zhong-Hua Sun
Journal:  J Geriatr Cardiol       Date:  2012-03       Impact factor: 3.327

6.  Endovascular repair during complex thoracic aortic dissection using a micropore stent graft: Midterm follow-up clinical outcomes.

Authors:  Zhe Wang; Cheng Wang; Fenghe Li; Yu Zhao
Journal:  Catheter Cardiovasc Interv       Date:  2019-08-13       Impact factor: 2.692

7.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.

Authors:  Fabian Springer; Roland Schlierf; Joachim-Georg Pfeffer; Andreas H Mahnken; Uwe Schnakenberg; Thomas Schmitz-Rode
Journal:  Eur Radiol       Date:  2007-03-06       Impact factor: 7.034

8.  Correlation between intrasac pressure measurements of a pressure sensor and an angiographic catheter during endovascular repair of abdominal aortic aneurysm.

Authors:  Pierre Galvagni Silveira; Christopher William Teixeira Miller; Rafael Freygang Mendes; Gilberto Nascimento Galego
Journal:  Clinics (Sao Paulo)       Date:  2008-02       Impact factor: 2.365

9.  Hemodynamic Functions of Fenestrated Stent Graft under Resting, Hypertension, and Exercise Conditions.

Authors:  Harkamaljot Singh Kandail; Mohamad Hamady; Xiao Yun Xu
Journal:  Front Surg       Date:  2016-06-14

10.  Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions.

Authors:  Harkamaljot Kandail; Mohamad Hamady; Xiao Yun Xu
Journal:  J Endovasc Ther       Date:  2016-05-25       Impact factor: 3.487

View more